IBM Support

PH51795: INTEGRITY CHECKER WILL CAUSE ABENDS0E0 WHEN IT VERIFIES DMB IN IMS ONLINE WITH SOME CONDITIONS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Integrity Checker will cause ABENDS0E0 when it verifies DMB for
    Full Function database in IMS Online. It also will cause
    ABENDS0E0 when it verifies DMB in IMS Online and DL/I SAS region
     is running. When Integrity Checker runs in these conditions, it
     will fail to initialize AR register. As a result of this, DBRC
    region ends with ABEND.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 2 (FMID=H27P220) users     *
    *                 who use the Integrity Checker utility.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Integrity Checker utility will cause    *
    *                      ABENDS0E0 when it verifies DMB in IMS   *
    *                      online with some conditions.            *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the Integrity Checker utility not to cause
    ABENDS0E0 when it verifies DMB in IMS online.
    
    When the Integrity Checker verifies DMB in IMS online and it
    verifies DMB in IMS online with DL/I SAS region or it verifies
    DMB for full function database in IMS online, it uses AR mode.
    
    The Integrity Checker clears AR registers before use. However
    the variable to use clear AR registers was pointed by some
    GPR register, the associated AR register itself was not cleared
    when used. As a result of this, ABENDS0E0 was occurred.
    
    This APAR fixes the Integrity Checker utility to clear the AR
    register and the GPR register before use.
    

Problem conclusion

  • The following modules and macros have been changed to fix the
    problem:
    FABLVDVF, FABLVMNF, FABLVDV0, FABLVMN0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH51795

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-01-10

  • Closed date

    2023-01-24

  • Last modified date

    2023-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FABLVDVF FABLVMNF
    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R220 PSY UI90232

       UP23/01/26 P F301

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.