A fix is available
APAR status
Closed as program error.
Error description
After application of the PTFs for APAR PH37147, when a CMAS looses contact with a remote CMAS in the CICSPlex, the remote MAS regions are marked as lostcon. This results in workloads they are target regions for to be frozen. However if one of the remaining CMAS regions have a CPSM cold start, and following CPSM warm starts, the active CMAS region will incorrectly mark the MAS regions as gone, resulting in message EYUWM0425I : EYUWM0425I <applid> Target region (MAS0001) for CICSplex (CPLX0001) has been terminated in workload EYUWM0425I <applid> (WLM0001). If this was the only target region in a lost state in the workload, this results in the workload incorrectly being defrosted with message : EYUWM0413I <applid> Workload (WLM0001) from context (CPLX0001) has been reactivated from Frozen.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM Users. * **************************************************************** * PROBLEM DESCRIPTION: A CMAS incorrectly reports message * * EYUWM0425I, that a target MAS region * * has been terminated in a workload after * * a restart. This results in the workload * * being incorrectly defrosted on that * * CMAS with message EYUWM0413I. * **************************************************************** * RECOMMENDATION: Apply the PTFs for this APAR to all CMAS * * regions and restart. This can be done in any * * order. * **************************************************************** When a CMAS with connected MAS regions stops, the other CMAS regions set these remote MAS regions as LOSTCON in their topology and WLM data spaces, and freeze workloads in which these MASs participate. A CPSM cold start of one of the active CMAS regions participating in the workload results in the workload being imported from other active CMAS regions when a MAS in the workload connects after the cold start. This causes topology information for the remote LOSTCON MAS regions to be acquired. However, after this CMAS subsequently performs a CPSM warm start, some of the imported data can be lost. This occurs due to incorrect logic added by PH37147. Topology changes the status of the MAS to gone. This results in the WLM component being informed, terminating the MAS from the workload and defrosting it, while the MAS is still actively running, This is shown with message : EYUWM0425I <applid> Target region (<mas>) for CICSplex (<cicsplex>) has been terminated in workload EYUWM0425I <applid> (<workload>). followed by EYUWM0413I <applid> Workload (<workload>) from context (<cicsplex>) has been reactivated from Frozen.
Problem conclusion
The topology warm start logic modified by APAR PH37147 has been corrected, to properly determine if MAS region is LOSTCON or GONE in this case, to ensure topology and associated WLM workloads are in the correct state, and workloads are not incorrectly defrosted when remote MAS regions may still be operating.
Temporary fix
Comments
APAR Information
APAR number
PH51351
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
10M
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-12-07
Closed date
2023-01-09
Last modified date
2023-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH51654 UI83955 UI83956 UI83957
Modules/Macros
EYU0TIWS
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R10M PSY UI83957
UP23/01/18 P F301 {
R20M PSY UI83956
UP23/01/18 P F301 {
R30M PSY UI83955
UP23/01/18 P F301 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: