A fix is available
APAR status
Closed as program error.
Error description
A COBOL compile with OPT(0),INITCHECK gives the following compiler error: IGYCB7104-U Internal error while compiling program XXXX. Failed assertion on ../../trwcode/optimizer/CICSExceptionAnalyzer.cpp:1016. Compilation terminated. Assertion failed at ../../trwcode/optimizer/CICSExceptionAnalyzer.cpp:1016: fallThroughBlock != NULL Expecting CICS call to have a fallthrough block
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling * * programs at OPT(0) that contain EXEC CICS * * IGNORE CONDITION statements * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYCB7104-U Internal error while * * compiling function XXXXX. Failed * * assertion ../../trwcode/optimizer/ * * CICSExceptionAnalyzer.cpp:1016 * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler's internal state was incorrect when optimizing CICS calls and the compiler abended when it detected that its internal state was correct.
Problem conclusion
The compiler was fixed to have correct internal state when optimizing CICS calls
Temporary fix
Comments
APAR Information
APAR number
PH50303
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-19
Closed date
2022-10-20
Last modified date
2022-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI82927
UP22/10/28 P F210
R621 PSY UI82928
UP22/10/28 P F210
R622 PSY UI82929
UP22/10/28 P F210
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023