A fix is available
APAR status
Closed as program error.
Error description
If FFFFFFFFFFFFFFFFFFFF LRSN is chosen as a recovery LRSN for restoring a data sharing member, a conditional restart record is not inserted for the member, and a job with RESTORE SYSTEM LOGONLY fails with the error: DSNU1612I RESTORE SYSTEM UTILITY FAILED BECAUSE THE SYSTEM IS NOT IN SYSTEM RECOVER PENDING STATE.
Local fix
Problem summary
If FFFFFFFFFFFFFFFFFFFF LRSN is chosen as a recovery LRSN for restoring a data sharing member, a conditional restart record is not inserted for the member, and a job with RESTORE SYSTEM LOGONLY fails with the error: DSNU1612I RESTORE SYSTEM UTILITY FAILED BECAUSE THE SYSTEM IS NOT IN SYSTEM RECOVER PENDING STATE.
Problem conclusion
Apply the PTF.
Temporary fix
Comments
APAR Information
APAR number
PH50179
Reported component name
DB2 REC EXPERT
Reported component ID
5697H7400
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-13
Closed date
2022-11-09
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI83198
Modules/Macros
ARY#YARC ARY@APRN ARY@CRCR
Fix information
Fixed component name
DB2 REC EXPERT
Fixed component ID
5697H7400
Applicable component levels
R320 PSY UI83198
UP22/12/01 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: