APAR status
Closed as program error.
Error description
Application Discovery fix pack level - 6.0.2 ifix2 Getting following error, Error [120] : The Lexer detected unknown combination: 'COPY' for the following code snipped: ================================================== COPY BV1ERCIC. COPY BV1ERGEN REPLACING GOBACK BY ==PERFORM D1000-TERMINATION== ==================================================
Local fix
Add a "." at the end of instruction - after the == signs: COPY BV1ERGEN REPLACING GOBACK BY ==PERFORM D1000-TERMINATION==.
Problem summary
The Lexer detected unknown combination: 'COPY' At the compilation stage of project building, the above error was occurring when parsing a 'COPY ... REPLACING' statement on the last lines of a COBOL file.
Problem conclusion
A fix was applied in code, and now this issue is solved, and that error is not appearing anymore.
Temporary fix
Comments
APAR Information
APAR number
PH49855
Reported component name
AD MAINFRAME
Reported component ID
5737B1610
Reported release
602
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-09-28
Closed date
2022-12-06
Last modified date
2023-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AD MAINFRAME
Fixed component ID
5737B1610
Applicable component levels
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O","label":"IBM Application Discovery"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"602"}]
Document Information
Modified date:
02 June 2023