  • The started task abends when it does not have read access to a
    member it is attempting to back up.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM z/OS Change Tracker.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. The started task abends with message *
    *                         ICH408I INSUFFICIENT ACCESS          *
    *                         AUTHORITY when it does not have read *
    *                         access to a member it is attempting  *
    *                         to back up.                          *
    *                      2. The SURVEILLANCE command abends with *
    *                         message ICH408I INSUFFICIENT ACCESS  *
    *                         AUTHORITY when it does not have read *
    *                         access to a specified data set.      *
    *                      3. The started task protection list is  *
    *                         not always refreshed when a data set *
    *                         is protected, re-protected or        *
    *                         unprotected.                         *
    *                      4. Message CYG427I is not documented in *
    *                         the manual and the displayed return  *
    *                         code is incorrect.                   *
    *                      5. Message CYG266W incorrectly refers   *
    *                         to the REPROTECT command.            *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    1. When a member of a protected PDSE data set is changed and the
       started task attempts to back up that member, and the started
       task does not have READ access to that data set, the started
       task abends with a ICH408I INSUFFICIENT ACCESS AUTHORITY
       message.
    2. When a user runs the SURVEILLANCE command for a data set that
       the user does not have READ access to, the job abends with a
       ICH408I INSUFFICIENT ACCESS AUTHORITY message.
    3. Sometimes the started task protection list is not refreshed
       after a PROTECT, REPROTECT or UNPROTECT command is
       successfully run.
    4. Message CYG427I is missing from the manual and the return
       code displayed in the message is incorrect.
    5. Message CYG266W should refer to the PROTECT not the REPROTECT
       command.
    

Problem conclusion

  • 1. When a member of a protected PDSE data set is changed and the
       started task attempts to back up that member, and the started
       task does not have READ access to that data set, message
       'CYG411W Member not backed up. READ access required.' will be
       issued. The started task will no longer abend.
    2. Message 'CYG210W READ access required for surveillance.' will
       be issued when the SURVEILLANCE command is run by a user that
       does not have READ access to a specified data set. The job
       will no longer abend.
    3. The started task protection list will always refresh after a
       PROTECT, REPROTECT or UNPROTECT command is successfully run.
    4. Message CYG427I will be added to the manual and the correct
       return code will be displayed.
    5. Message CYG266W will be changed to say 'UNPROTECT and then
       PROTECT the resource'.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH49225

  • Reported component name

    Z/OS CHANGE TRA

  • Reported component ID

    5752SCCYG

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-02

  • Closed date

    2022-10-11

  • Last modified date

    2022-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI82801

Modules/Macros

  • CYGCOMM  CYGMAIN  CYGMOD   CYGPROC  CYGSTC   CYGSYSO  CYGTKREF
    

Fix information

  • Fixed component name

    Z/OS CHANGE TRA

  • Fixed component ID

    5752SCCYG

Applicable component levels

  • R100 PSY UI82801

       UP22/10/28 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"100"}]

Document Information

Modified date:
01 November 2022