A fix is available
APAR status
Closed as program error.
Error description
A s0c4 can occur in COBOL run-time routine IGZXSPA when writing past the end of volume of a file that is coded with WRITE AFTER ADVANCING. Also, the file is defined with a File Status clause, but the file status is not checked.
Local fix
Do not write past the end of volume.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 and later * * releases running AMODE 64 programs writing * * to QSAM files with a WRITE AFTER ADVANCING * * clause and FILE STATUS clause specified. * **************************************************************** * PROBLEM DESCRIPTION: When the program writes to a QSAM file * * past end of volume, an 0C4 abend * * may occur in COBOL run-time routine * * IGZQSPA and the program terminates. * **************************************************************** * RECOMMENDATION: Install the provided PTF. * **************************************************************** The COBOL run-time routine IGZQSPA attempts to refer to an invalid buffer address assigned when writing past end of volume. COB0603T/K COB0604T/K
Problem conclusion
The COBOL Runtime logic has been fixed. The file status is set with 34 when writing past end of volume with a WRITE AFTER ADVANCING clause on a QSAM file specified with the FILE STATUS clause in the file definition. In order for the COBOL program to continue, it needs to take appropriate action to handle the file status 34 as described in COBOL Programming Guide - Chapter 9. Processing QSAM Files -- Handling errors in QSAM files "If you use the FILE STATUS clause, be sure to check the key and take appropriate action based on its value. If you do not check the key, your program might continue, but the results will probably not be what you expected." The meaning of 'File status 34' can be found from COBOL Language Reference - Chapter 26. Procedure division structure -- Statement operations --- Common processing facilities ----- File status key "Permanent error condition A permanent error exists because of a boundary violation; an attempt was made to write beyond the externally defined boundaries of a sequential file."
Temporary fix
Comments
APAR Information
APAR number
PH48843
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7D0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-08-22
Closed date
2022-09-27
Last modified date
2022-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI82579 UI82580 UI82584
Modules/Macros
CELQSG04 CELQV004 IGZQAPI IGZQCA64 IGZQCDA IGZQINPL IGZQJNI2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI82579
UP22/10/01 P F209
R7C0 PSY UI82580
UP22/10/01 P F209
R7D0 PSY UI82584
UP22/10/01 P F209
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7D0","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: