PH47959: CICS SHUTDOWN HANGS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The customer issues an EXEC CICS PERFORM SHUTDOWN from their own
    transaction but the shutdown hangs. The joblog confirms that
    CESD has ended all non-system tasks :
    
    03.00.24 JOB18746 +DFHCESD CICST22 SHUTDOWN ASSIST TRANSACTION
    CESD STARTING. SHUTDOWN IS NORMAL.
    ..
    03.00.57 JOB18746 +DFHTM1782I CICST22 All non-system tasks have
    been successfully terminated.
    
    This is followed by :
    
    03.01.03 JOB18746  +DFHZC2305I CICST22 Termination of VTAM
    sessions beginning
    
    Several minutes later the region is still running so the
    customer attempts to run their shutdown transaction again,
    
    but this fails :
    
    
    03.08.50 JOB18746  +DFHAC2007 05/01/2022 03:08:50 CICST22
    Transaction xxxx cannot run as CICS shutdown is in progress.
    
    and they eventually cancel the region.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: CICS hangs during normal shutdown when  *
    *                      two attempts to issue CNOS to zero      *
    *                      for a parallel LU6.2 connection fail    *
    *                      with SEND errors.                       *
    ****************************************************************
    A CICS region specifies DFHSIT parameters TCSACTN=FORCE and
    TCSWAIT with a numerical threshold value. These are set to
    request that CICS terminal control takes action to forceclose
    the CICS z/OS Communications Server ACB after the threshold time
    expires during normal shutdown.
    
    During a normal shutdown, a request for CNOS (change number of
    sessions) to zero is sent across a parallel LU6.2 connection and
    an error response is returned with message DFHZC0161 and error
    code X'FBB1'.
    
    DFHZC0161 date time applid CLS1 CNOS command for modename MNAME
    to node NETNAME connection SYSID has failed with code X'FBB1'.
    
    CICS retries the CNOS request but this SEND also fails with the
    same message and error code. The failure to successfully
    complete CNOS close processing prevents the TCSACTN=FORCE action
    from taking place.
    
    Additional keywords: ZC0161 MSGDFHZC0161
    

Problem conclusion

  • CICS is changed to allow the TCSACTN=FORCE action to go ahead
    and forceclose the CICS z/OS Communications Server ACB if
    a second attempt to complete CNOS close processing, for an LU62
    parallel connection, returned a SEND error with message
    DFHZC0161 and code X'FBB1'.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH47959

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-07-13

  • Closed date

    2022-07-20

  • Last modified date

    2022-09-01

  • APAR is sysrouted FROM one or more of the following:

    PH44682

  • APAR is sysrouted TO one or more of the following:

    UI81571

Modules/Macros

  • DFHBSSZ  DFHTCTTE DFHTCTZE DFHZGCN  DFHZSHU
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UI81571

       UP22/08/03 P F208