IBM Support

PH46802: UNEXPECTED IGZ0278S WHEN USING SD SORTFILE FOR SORT WITH NUMCHECK OPTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Unexpected IGZ0278S when using SD SORTFILE for SORT with
    NUMCHECK option
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and  *
    *                 running a program compiled with the NUMCHECK *
    *                 option where the program contains a SORT     *
    *                 statement specifying at least one sort       *
    *                 keypart that is of a type covered by the     *
    *                 NUMCHECK option in effect.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Runtime abend or message (depending on  *
    *                      NUMCHECK setting), with message text    *
    *                      such as:                                *
    *                                                              *
    *                      IGZ0279W The value X'0000' of data      *
    *                      item SORT-INST-NO at the time of        *
    *                      reference by statement number 1 on      *
    *                      line 97 in program PROBLM2 failed       *
    *                      the NUMERIC class test or               *
    *                      contained a value larger than the       *
    *                      PICTURE clause as detected              *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF.                  *
    ****************************************************************
    NUMCHECK checking was sometimes being inadvertently applied to
    sort keyparts during the setup of a sort when there was no valid
    data in the sort record.
    

Problem conclusion

  • The compiler was updated to ensure that numchecking sort
    keyparts during the setup of a sort is never done.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH46802

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-05-31

  • Closed date

    2022-07-22

  • Last modified date

    2022-08-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH47291 PH48672

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI  IGYCOSCN IGYCPGEN IGYCRCTL
    IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0
    IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D
    IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT
    IGYQCB   IGYQCBE  IGYQCBG  IGYQSPLT IGYTCARA IGYTSALE IGYZQEN6
    IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI81630

       UP22/07/29 P F207

  • R631 PSY UI81631

       UP22/07/29 P F207

  • R632 PSY UI81632

       UP22/07/29 P F207

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: