A fix is available
APAR status
Closed as program error.
Error description
Unexpected IGZ0278S when using SD SORTFILE for SORT with NUMCHECK option
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and * * running a program compiled with the NUMCHECK * * option where the program contains a SORT * * statement specifying at least one sort * * keypart that is of a type covered by the * * NUMCHECK option in effect. * **************************************************************** * PROBLEM DESCRIPTION: Runtime abend or message (depending on * * NUMCHECK setting), with message text * * such as: * * * * IGZ0279W The value X'0000' of data * * item SORT-INST-NO at the time of * * reference by statement number 1 on * * line 97 in program PROBLM2 failed * * the NUMERIC class test or * * contained a value larger than the * * PICTURE clause as detected * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF. * **************************************************************** NUMCHECK checking was sometimes being inadvertently applied to sort keyparts during the setup of a sort when there was no valid data in the sort record.
Problem conclusion
The compiler was updated to ensure that numchecking sort keyparts during the setup of a sort is never done.
Temporary fix
Comments
APAR Information
APAR number
PH46802
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-05-31
Closed date
2022-07-22
Last modified date
2022-08-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCB IGYQCBE IGYQCBG IGYQSPLT IGYTCARA IGYTSALE IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI81630
UP22/07/29 P F207
R631 PSY UI81631
UP22/07/29 P F207
R632 PSY UI81632
UP22/07/29 P F207
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: