A fix is available
APAR status
Closed as program error.
Error description
After applying PH42885 a thread could experience excessive CPU usage during SQL data collection. Other symptoms could be internal DDX diagnostic traps or abend0cx.
Local fix
Set startup parameter OBJECTS to OBJECTS(N). This will force CQM to skip object collection and thus remove the incorrout exposure.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 Query Monitor * **************************************************************** * PROBLEM DESCRIPTION: High CPU and incorrout seen after * * PH42885 * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** After applying PH42885 a thread could experience excessive CPU usage during SQL data collection. Other symptoms could be internal DDX diagnostic traps or ABEND0Cx.
Problem conclusion
The problem was isolated to invalidating some objects collected
Temporary fix
Comments
APAR Information
APAR number
PH45542
Reported component name
COMMON COLLECTO
Reported component ID
5639OLC00
Reported release
110
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-04-08
Closed date
2022-04-25
Last modified date
2022-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80307
Modules/Macros
CQCEUFC5 CQCMABD5 CQCMALOX CQCMB2C5 CQCMB2D5 CQCMB3C5 CQCMB3D5 CQCMB4C5 CQCMB4D5 CQCMBNC5 CQCMBND5 CQCMBRC5 CQCMBRD5 CQCMC1D5 CQCMC2C5 CQCMC2D5 CQCMCLD5 CQCMCMC5 CQCMCMD5 CQCMCMDS CQCMCNC5 CQCMCND5 CQCMCOC5 CQCMCOD5 CQCMCRD5 CQCMCXD5 CQCMDLC5 CQCMDLD5 CQCMDZC5 CQCMDZD5 CQCMESB1 CQCMESC5 CQCMESD5 CQCMFRC5 CQCMFRD5 CQCMINSD CQCMINST CQCMLCD5 CQCMLRD5 CQCMPRD5 CQCMR1D5 CQCMRLC5 CQCMRLD5 CQCMRRD5 CQCMSCLN CQCMSIC5 CQCMSID5 CQCMSRD5 CQCMTPC5 CQCMTPD5 CQCMTRC5 CQCMTRD5 CQCMUGC5 CQCMUGD5 CQCMZBC5 CQCMZBD5 CQCOXGBX CQCOXGC5 CQCOXGD5 CQCPCR1X CQCTEDC5 CQCTEDD5 CQCTK1C5 CQCTK1D5 CQCTK2C5 CQCTK2D5 CQCTK3C5 CQCTK3D5 CQCTK4C5 CQCTK4D5 CQCTK5C5 CQCTK5D5 CQCTK6C5 CQCTK6D5 CQCTK9C5 CQCTK9D5 CQCTTEX1 CQCTXLC5 CQCTXLD5
Fix information
Fixed component name
COMMON COLLECTO
Fixed component ID
5639OLC00
Applicable component levels
R110 PSY UI80307
UP22/04/29 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date: