Error description
ABEND0C4 occurs in the IBSCAN module IIUFOINT when a prime database is an OSAM data set with volume of 21 or more.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS Index Builder for z/OS, * * Version 3 Release 1 (FMID=H22O310) * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in the IBSCAN module IIUFOINT * * when scanning OSAM with volume of 21 or * * more. * **************************************************************** ABEND0C4 occurs in the IBSCAN module IIUFOINT when a prime database is an OSAM data set with volume of 21 or more.
Problem conclusion
IIUFOSAM has been modified to get volume list via UCB instead of using LOCATE and CAMLST when a prime database is an OSAM data set with volume of 20 or more.
Temporary fix
Comments
APAR Information
APAR number
PH45399
Reported component name
IMS INDEX BUILD
Reported component ID
5655E2400
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-04-01
Closed date
2022-04-14
Last modified date
2022-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80138
Modules/Macros
IIUFOSAM
Fix information
Fixed component name
IMS INDEX BUILD
Fixed component ID
5655E2400
Applicable component levels
R310 PSY UI80138
UP22/04/15 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.