A fix is available
APAR status
Closed as program error.
Error description
WEB PARSE URL truncating the query string when QUERYSTRLEN is bigger than 256 bytes
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: EXEC CICS WEB PARSE URL truncates * * query string if over 256 bytes * **************************************************************** An application uses EXEC CICS WEB PARSE URL with a URL that has a query string that is greater than 256 bytes. When the query string is returned to the program its length is correct but the data has been truncated.
Problem conclusion
DFHEIWB updated to correctly copy any size of query string
Temporary fix
Comments
APAR Information
APAR number
PH44997
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-18
Closed date
2022-07-14
Last modified date
2022-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PH47736 UI81469 UI81470
Modules/Macros
DFHEIWB
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
28 September 2022