APAR status
Closed as program error.
Error description
In IDz 15.0.3 while generating a zunit testcase, copybooks with redefine variables, the testcase fails and displays the following warning IGYDS1073-I message. This problem occurs when the user source is UTF-8, the default file encoding is UTF-8, and the source contains a LEVEL 88 occupying column 72 where multi-byte characters are defined in VALUE phase.
Local fix
N/A
Problem summary
The problem occurs while opening ZUnit test case editor, when the default file encoding is UTF-8, the source contains a level 88 occupying column 72 where multiple- byte characters are defined in VALUE phrase.
Problem conclusion
When the default file encoding is UTF-8, ZUnit will be able to handle multiple byte characters correctly.
Temporary fix
Comments
APAR Information
APAR number
PH44935
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
F00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-16
Closed date
2022-05-27
Last modified date
2023-09-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"F00"}]
Document Information
Modified date:
21 September 2023