A fix is available
APAR status
Closed as program error.
Error description
CEC Machine Type and Model information stored in the SMF 110 record is static as it was at startup time and doesn't change if the model number changes.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: SMF 110 field CECMDLID not updated * **************************************************************** When CICS initialises, it write an SMF 110 record containing the CEC Machine Type and Model. This may present as (eg: from running DFH0STAT): CEC Machine Type and Model. . : 2964-799 This field remains constant for the run of CICS. If additional engines are added and this number doesn't change then there is the potential to compromise capacity planning activities. Keywords: DEVELOPER WORKS 103473 DEVELOPERWORKS 103473 RFE138635 RFE 138635
Problem conclusion
DFHMNST runs when statistics recording is ON at a frequency set by the STATITICS INTERVAL value. When MNST runs it will refresh the CECMDLID value and write it as an SMF 110 record.
Temporary fix
Comments
APAR Information
APAR number
PH44072
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-02-11
Closed date
2022-04-07
Last modified date
2022-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80055
Modules/Macros
DFHMNST
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R200 PSY UI80055
UP22/04/08 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5"}]
Document Information
Modified date:
04 May 2022