Error description

  • Compiler abend with message MSGIGYCB7104-U   Internal error
    while compiling function 'XXXXX'. Failed assertion on
    ../il/Node.cpp:3022. Compilation terminated.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling      *
    *                 programs that contain an EVALUATE WHEN       *
    *                 statement, or an IF statement comparing one  *
    *                 data item to multiple constant values,       *
    *                 within a paragraph that is PERFORMed, where  *
    *                 the compiler is able to determine that the   *
    *                 data item being EVALUATED or compared has a  *
    *                 known value.                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abend with message             *
    *                      MSGIGYCB7104-U   Internal error while   *
    *                      compiling function XXXXX. Failed        *
    *                      assertion on ../il/Node.cpp:3022.       *
    *                      Compilation terminated.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    If the compiler sees an EVALUATE statement, or an IF statement
    comparing one data item to multiple constant values, and the
    data item being EVALUATEd or compared has a known value, the
    compiler simplifies the EVALUATE or compares by getting rid of
    the paths that can't be taken, and then, if there is only one
    path, turning the EVALUATE or comparisons into a single goto. If
     the EVALUATE or comparisons are within a paragraph that is
     PERFORMed, it's possible that EVALUATE or comparison statement
     is itself unreachable and may be removed as part of the
     compiler removing the unreachable branches. If this happens,
     the EVALUATE or comparison doesn't exist when the compiler
     tries to convert it to a single goto, so such a transformation
     isn't possible. The compiler asserts when this impossible state
      is detected.
    

Problem conclusion

  • The compiler was fixed to no longer attempt to convert the
    EVALUATE or comparisons into a single goto if the EVALUATE or
    comparisons were removed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH43250

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-01-12

  • Closed date

    2022-03-15

  • Last modified date

    2022-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH44350

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCB
    IGYQCBE  IGYQCBG  IGYQSPLT IGYTCARA IGYTSALE IGYZQEN6 IGYZQENU
    IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI79731

       UP22/03/26 P F203

  • R631 PSY UI79732

       UP22/03/26 P F203

  • R632 PSY UI79733

       UP22/03/26 P F203

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023