A fix is available
APAR status
Closed as program error.
Error description
MSGBBE3201E GETMAIN failed when the Integrated DB Sensor function was used in HD Pointer Checker jobs or HPIC FF DB HASH Check jobs.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who use FF Integrated DB Sensor in HD * * Pointer Checker (HDPC) stand-alone jobs or * * IMS High Performance Image Copy (HPIC) HASH * * Check jobs. * **************************************************************** * PROBLEM DESCRIPTION: FF DB Sensor issues MSGBBE3201E in HD * * Pointer Checker stand-alone jobs or * * HPIC HASH Check jobs. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When FF Integrated DB Sensor is used in HDPC stand-alone jobs or HPIC HASH Check jobs, Integrated DB Sensor calculates a GETMAIN size based on the incorrect list built by HDPC and can try to obtain too large amount of storage. As the result, a GETMAIN error is caused and FF Integrated DB Sensor issues BBE3201E GETMAIN FAILED message.
Problem conclusion
HPPC has been modified to build a correct list so that Integrated DB Sensor can calculate a correct GETMAIN size.
Temporary fix
Comments
APAR Information
APAR number
PH42677
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-12-09
Closed date
2021-12-20
Last modified date
2022-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI78650 UI78651
Modules/Macros
FABPSENR
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UI78651
UP21/12/22 P F112
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.