Error description
After re-partition, the last byte of a partition high key happens to be x'5E' which is equal to C';' (semicolon). HTK incorrectly treated the last byte x'5E' as a delimiter of an exit routine for partition selection (IHCPSEL0) provided by HTK. The keystring parameter of IHCPSEL0 is specified as ooo;lll;kkkkk. That caused the error message DSP1058I KEYSTRNG PARAMETER (HIGH KEY VALUE) IS TOO LONG.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS HALDB Toolkit 1.1. * **************************************************************** * PROBLEM DESCRIPTION: DSP1058I KEYSTRNG PARAMETER (HIGH KEY * * VALUE) IS TOO LONG received from * * ANALYZEPART and MAINTAIN functions. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the last byte of a partition high key happened to be x'5E' which is equal to C';' (semicolon) after re-partition, HTK incorrectly treated the last byte x'5E' as a delimiter of an exit routine for partition selection (IHCPSEL0) provided by HTK. The keystring parameter of IHCPSEL0 is specified as ooo;lll;kkkkk. That caused the error message DSP1058I KEYSTRNG PARAMETER (HIGH KEY VALUE) IS TOO LONG.
Problem conclusion
Code has been changed to generate the KEYSTRNG parameter correctly when the last byte of a partition high key happens to be x'5E'.
Temporary fix
Comments
APAR Information
APAR number
PH41431
Reported component name
IMS HALDB TOOLK
Reported component ID
5655DBU01
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-19
Closed date
2021-11-02
Last modified date
2021-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI77895
Modules/Macros
IHCULEV0 IHCWJCLG IHCWTDRC
Fix information
Fixed component name
IMS HALDB TOOLK
Fixed component ID
5655DBU01
Applicable component levels
R110 PSY UI77895
UP21/11/06 P F111