IBM Support

PH40863: IMPROVEMENTS TO CICS TS QUEUE SCAN LOGIC FOR DFHTSCL

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Improvements to CICS TS queue scan logic for DFHTSCL
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Performance issues when CICS performs a *
    *                      scan of TS queues to establish if any   *
    *                      can be deleted.                         *
    ****************************************************************
    You can use a TSMODEL to set an EXPIRY on a TS-queue.
    If you install such a TSMODEL in CICS, then CICS will initiate a
    SCAN process, that will scan main/auxilliary and Coupling
    Facility (CF) Temporary Storage pools for expired TS queues.
    
    This scan process will run in all CICS regions that have a
    TSMODEL with an EXPIRY specified.
    The scan will run with an interval of 1/10 of the lowest EXPIRY
    interval or one minute, whichever is the larger.
    For example, if you have two TSMODELs, one with:
    EXPIRY=10(minutes) and one with EXPIRY=30(minutes), then the
    scan process will run every 1 minute in each CICS region that
    has the TSMODEL installed.
    Even when the TSMODEL specifies no POOL (i e local queues) both
    MAIN/AUXILARY and all CF TS Pools are scanned every minute.
    

Problem conclusion

  • The code that scans Temporary Storage queues has been amended
    to improve its performance.
    
    There are documentation updates associated with this APAR and
    will appear in an update of the IBM Knowledge Centre for CICS.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH40863

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    300

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-24

  • Closed date

    2022-02-11

  • Last modified date

    2022-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI79275

Modules/Macros

  • DFHECEAT DFHEIIC  DFHEIQTS DFHEITS  DFHESE   DFHMETSC DFHMETSE
    DFHMETSK DFHMIRS  DFHMQBID DFHMQCM@ DFHMQP0@ DFHMQP1@ DFHMQP3@
    DFHMQR0@ DFHRLRO  DFHSIPLT DFHTSAD  DFHTSAM  DFHTSBR  DFHTSCL
    DFHTSDM  DFHTSDQ  DFHTSDUC DFHTSDUF DFHTSDUS DFHTSITR DFHTSMB
    DFHTSMBT DFHTSP   DFHTSPT  DFHTSQR  DFHTSRM  DFHTSSH  DFHTSSQ
    DFHTSSR  DFHTSST  DFHTSWQ  DFHWBQM
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R300 PSY UI79275

       UP22/02/22 P F202

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.6"}]

Document Information

Modified date:
02 March 2022