IBM Support

PH40311: ADD SUPPORT FOR THE NEW >>DATA DIRECTIVE FOR AMODE 64 COBOL PROGRAMS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Add support for the new >>DATA directive for AMODE 64 COBOL
    programs.  It allows the compiler user to control the AMODE of
    identifiers defined in the WORKING-STORAGE section of the
    source program.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.3 who are       *
    *                 compiling programs with the LP(64) compiler  *
    *                 option in effect and would like to have the  *
    *                 flexibility to choose the storage location   *
    *                 of certain data items defined in the         *
    *                 WORKING-STORAGE section of the source        *
    *                 program.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: New Function: When LP(64) is in effect, *
    *                      by default data items in the            *
    *                      WORKING-STORAGE section reside above    *
    *                      the bar. This can be changed by using   *
    *                      a new compiler directive >>DATA.        *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM provided PTF and make use of   *
    *                 the new >>DATA directive, as appropriate.    *
    ****************************************************************
    When LP(64) is in effect, by default data items in the
    WORKING-STORAGE section reside above the 2GB bar.  Until now,
    a compiler user had no way to specify the storage location as
    below the 2GB bar for data items defined in the WORKING-STORAGE
    section.
    

Problem conclusion

Temporary fix

Comments

  • A new >>DATA directive has been added to the compiler to allow
    the user to specify the storage location of data items
    defined in the WORKING-STORAGE section of the source program.
    The >>DATA directive syntax is defined as follows:
    
    
    >>----- >>DATA --integer-1-----<<
    
    where integer-1 must be an unsigned integer with a value of
    64 or 31. The default for LP(64) is 64. The directive is not
    supported in LP(32).
    
    >>DATA 31 specifies that storage should reside below the
    2GB bar
    >>DATA 64 specifies that storage could reside above the
    2GB bar
    

APAR Information

  • APAR number

    PH40311

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-01

  • Closed date

    2021-09-27

  • Last modified date

    2021-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI77327 UI77328 UI77329 UI77330

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI  IGYCOPT  IGYCOSCN
    IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN
    IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5
    IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE
    IGYMSGK  IGYMSGT  IGYQCBE  IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU
    IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI77327

       UP21/10/01 P F109

  • R631 PSY UI77328

       UP21/10/01 P F109

  • R632 PSY UI77329

       UP21/10/01 P F109

  • R63H PSY UI77330

       UP21/10/01 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: