Error description
Reworked sample configurations Better diagnostics Performance enhancements
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Z Performance and Capacity * * Analytics Version 3.1.0 making use of the * * DataImporter. * **************************************************************** * PROBLEM DESCRIPTION: Errors occur in the ELK reports when * * fields in the DB2 table have null * * values. * **************************************************************** * RECOMMENDATION: Apply the provided PTFs. * **************************************************************** If a field in the extracted data from DB2 has a null value, the DataImporter excludes the field name and field value when creating the JSON file. As a result, the JSON file, produced by the DataImporter, may have a different number of the fields than is expected by the ELK report. This causes an error in the ELK report.
Problem conclusion
The DataImporter is modified to set a default value instead of null when it outputs the JSON file. By setting a default value, the JSON file created by the DataImporter includes all of the field names and the value in each record. The DataImporter feature forceFields in the process stage is an optional function, enabling the user to control the value for null fields by setting Yes or No value in the configuration file.
Temporary fix
Comments
APAR Information
APAR number
PH40134
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
CA0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-25
Closed date
2022-03-23
Last modified date
2022-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI79844 UI79846
Modules/Macros
DRLDOD39 DRLPJCO DRLPJDI DRLPJDM DRLPJDS DRLPJSD DRLPJSM
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"CA0"}]
Document Information
Modified date:
02 April 2022