IBM Support

PH39253: PROGRAM EXCEPTION WHEN CALLING COBOL NESTED PROGRAM FROM COBOL PROGRAM THAT USES AN ALTERNATE ENTRY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A COBOL program that is using an Alternate Entry point
    attempts to call a nested program  But an exception occurs, as
    the address for the nested program has not been properly set.
    The exception can vary (could be s0c1, s0c4, or other s0cx),
    depending on what is in storage.
    

Local fix

  • Don't call a nested program from a program that uses an
    alternate entry point.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and  *
    *                 running a program that calls another         *
    *                 program through an alternate entry point     *
    *                 and where the code in that alternate entry   *
    *                 calls a nested program by identifier.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Runtime abend (0C1, 0C4, or 0C6)        *
    *                                                              *
    *                      For example:                            *
    *                                                              *
    *                      CEE3201S The system detected an         *
    *                      operation exception (System Completion  *
    *                      Code=0C1).                              *
    *                                                              *
    *                      From compile unit COBSUB1 at entry      *
    *                      point ALTENTR at compile unit offset    *
    *                      +004D3D08 at entry offset +004D3AF4 at  *
    *                      address 26DE0670.                       *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF.                  *
    ****************************************************************
    A list of information needed by COBOL runtime routine IGZXSCC1
    was only being initialized at runtime when called through the
    main entry point of a program, but that list is also needed in
    alternate entry points when calling nested programs.
    

Problem conclusion

  • The compiler was updated to ensure that the list of information
    needed by COBOL runtime routine IGZXSCC1 is initialized upon
    entry to an alternate entry that calls a nested program.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH39253

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-07-23

  • Closed date

    2021-07-23

  • Last modified date

    2021-08-09

  • APAR is sysrouted FROM one or more of the following:

    PH34560

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE
    IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI76440

       UP21/07/30 P F107

  • R631 PSY UI76441

       UP21/07/30 P F107

  • R632 PSY UI76442

       UP21/07/30 P F107

  • R63H PSY UI76443

       UP21/07/30 P F107

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023