IBM Support

PH38499: THE INTEGER-OF-FORMATTED-DATE INTRINSIC FUNCTION DOES NOT HONOR THE INTDATE COMPILER OPTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Although the other intrinsic date functions do honor the
    setting of the starting date based on the INTDATE(ANSI/LILIAN)
    compiler option, the INTEGER-OF-FORMATTED-DATE intrinsic
    function does not honor the INTDATE compiler option.
    
    Instead, the Language Reference at
    https://www.ibm.com/docs/en/cobol-zos/6.3?topic=functions-intege
    r-formatted-date documents that it always uses the starting
    date of Jan 1, 1601, i.e. INTDATE(ANSI).  This can cause
    unexpected results if INTDATE(LILIAN) is used.
    
    The INTEGER-OF-FORMATTED-DATE intrinsic function is being
    modified to honor the INTDATE compiler options to bring it in
    line with the other intrinsic date functions.
    
    The Language Reference will be updated as well to reflect this
    change.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and  *
    *                 running programs that are compiled with the  *
    *                 INTDATE(LILIAN) compiler option in effect    *
    *                 and the program uses the                     *
    *                 INTEGER-OF-FORMATTED-DATE intrinsic          *
    *                 function.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect result.  The return value of  *
    *                      the INTEGER-OF-FORMATTED-DATE function  *
    *                      is calculated as if the INTDATE(ANSI)   *
    *                      compiler option were in effect.         *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF.                  *
    ****************************************************************
    The INTEGER-OF-FORMATTED-DATE intrinsic function was not
    properly accounting for the INTDATE(LILIAN) compiler option.
    

Problem conclusion

  • The compiler was updated to ensure that it properly takes
    account of the INTDATE(LILIAN) compiler option when
    processing the INTEGER-OF-FORMATTED-DATE
    intrinsic function.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH38499

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-28

  • Closed date

    2021-09-27

  • Last modified date

    2021-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI  IGYCOPT  IGYCOSCN
    IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN
    IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5
    IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE
    IGYMSGK  IGYMSGT  IGYQCBE  IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU
    IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI77327

       UP21/10/01 P F109

  • R631 PSY UI77328

       UP21/10/01 P F109

  • R632 PSY UI77329

       UP21/10/01 P F109

  • R63H PSY UI77330

       UP21/10/01 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: