IBM Support

PH38148: JSON GENERATE DOES NOT HONOR THE TRUNC(BIN) COMPILER OPTION AND INCORRECTLY REQUIRES DATA TO FIT INTO THE PICTURE CLAUSE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • With TRUNC(BIN), a JSON GENERATE of a 5-digit data value into a
    PIC S9(4) BINARY data item truncates the high order digit,
    moving only the lower 4 of the 5 digits into the receiving field
    (i.e. it aligns at the decimal point and then the left-most
    digit is truncated).  TRUNC(BIN) does not seem to be honored
    with JSON GENERATE and the data is truncated to fit into its
    picture clause.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling     *
    *                 and running programs containing the JSON     *
    *                 GENERATE or XML GENERATE statement with the  *
    *                 TRUNC(BIN) compiler option in effect.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: In some cases the generated XML and/or  *
    *                      JSON may contain numeric values that    *
    *                      do not respect the TRUNC(BIN)           *
    *                      truncation rules when the TRUNC(BIN)    *
    *                      option is in effect..                   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    In some cases the compiler was generating code that did not
    respect the TRUNC(BIN) option in cases where the XML GENERATE
    and JSON GENERATE statements were producing output from numeric
    COBOL data items.
    

Problem conclusion

  • The compiler was changed to generate the correct code.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH38148

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-15

  • Closed date

    2021-07-23

  • Last modified date

    2021-08-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH39966

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE
    IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI76440

       UP21/07/30 P F107

  • R631 PSY UI76441

       UP21/07/30 P F107

  • R632 PSY UI76442

       UP21/07/30 P F107

  • R63H PSY UI76443

       UP21/07/30 P F107

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: