IBM Support

PH35601: NEW FUNCTION: IMPROVED PERFORMANCE OF ABO GENERATED MODULES THATCONTAIN SET INDEX1 TO INDEX2 STATEMENTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • NEW FUNCTION: Improved performance of ABO generated modules that
    contain SET INDEX1 to INDEX2 statements
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Automatic Binary Optimizer      *
    *                 (ABO) for z/OS, 2.1 and ABO for z/OS 2.1     *
    *                 Trial                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: This new function APAR adds             *
    *                      performance improvements                *
    *                      for ABO-optimized                       *
    *                      modules compiled                        *
    *                      from source containing                  *
    *                      SET INDEX1 to INDEX2 statements         *
    *                      when specifying the ABO option          *
    *                      ARCH=12 or higher.                      *
    *                                                              *
    *                      INDEX1 and INDEX2 in the example        *
    *                      SET statement above are the             *
    *                      names of data items                     *
    *                      declared by using the INDEXED           *
    *                      BY phrase of the OCCURS                 *
    *                      clause:                                 *
    *                                                              *
    *                                                              *
    *                      Example:                                *
    *                                                              *
    *                      05 TABLE-ITEM-1 PIC X(8)                *
    *                          OCCURS 10 INDEXED BY INDEX1         *
    *                                                              *
    *                      05 TABLE-ITEM-2 PIC X(5)                *
    *                          OCCURS 20 INDEXED BY INDEX2         *
    *                                                              *
    *                          SET INDEX1 to INDEX2                *
    *                                                              *
    *                                                              *
    *                      Performance improvements are            *
    *                      also likely when specifying ARCH=12     *
    *                      or higher for COMPUTE statements        *
    *                      involving division, or DIVIDE           *
    *                      statements, where the dividend          *
    *                      is binary data item with 10 or          *
    *                      more digits and the divisor is          *
    *                      a fixed point numeric literal.          *
    *                                                              *
    *                      Example:                                *
    *                                                              *
    *                      01 VAR-1 PIC 9(10) COMP.                *
    *                      01 VAR-2 PIC 9(10) COMP.                *
    *                                                              *
    *                      COMPUTE VAR-1 = VAR-2 / 61              *
    ****************************************************************
    * RECOMMENDATION: Apply provided service                       *
    ****************************************************************
    ABO was modified to improve the performance of ABO-optimized
    modules.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH35601

  • Reported component name

    AUTO BINARY OPT

  • Reported component ID

    5697AB200

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-22

  • Closed date

    2021-04-01

  • Last modified date

    2021-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • BOZBXITA BOZEXE1  BOZJIVP  BOZMSGE  BOZMSGK  BOZMSGT  BOZOBJ1
    BOZOPT   BOZPA    BOZPAJ   BOZRIDT  BOZSMF   BOZSMFJ  BOZSMFR
    BOZSRC1
    

Fix information

  • Fixed component name

    AUTO BINARY OPT

  • Fixed component ID

    5697AB200

Applicable component levels

  • R210 PSY UI74718

       UP21/04/07 P F104

  • R21J PSY UI74719

       UP21/04/07 P F104

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"210"}]

Document Information