Error description
QM can leak some memory when long running threads are still running after the QM deactivate function is issued against a QM subsystem, CQM12* messages maybe issued and CQM will not collect metrics until the next interval.
Local fix
Periodically recycle QM, as much as once a week in very busy Db2 environments.
Problem summary
**************************************************************** * USERS AFFECTED: Users of: * * IBM Db2 Query Monitor for z/OS * * IBM Security Guardium S-TAP for Db2 on z/OS * **************************************************************** * PROBLEM DESCRIPTION: Memory leak after deactivating * * monitoring of a QM subsystem when * * workloads are running, CQM12* messages. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Query Monitor can leak some memory when long running threads are still running after the Query Monitor deactivate function is issued against a Query Monitor subsystem. CQM12* messages maybe issued in such case and Query Monitor will not collect metrics until the next interval.
Problem conclusion
Logic was changed to correct memory release when Query Monitor subsystem was deactivated but some threads were still running. Search Keywords: MEMORY LEAK DEACTIVATE
Temporary fix
Comments
APAR Information
APAR number
PH34941
Reported component name
COMMON COLLECTO
Reported component ID
5639OLC00
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-01
Closed date
2021-06-16
Last modified date
2021-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQC#CSAL CQC#REST CQCMC1B1 CQCMC1C5 CQCMCRB1 CQCMCRC5 CQCMDLB1 CQCMDLC5 CQCMDZB1 CQCMDZC5 CQCMINST CQCMLCB1 CQCMLCC5 CQCMLRB1 CQCMLRC5 CQCMMFRR CQCMPRB1 CQCMPRC5 CQCMR1B1 CQCMR1C5 CQCMRRB1 CQCMRRC5 CQCMSCLN CQCMSCLS CQCOXGBX CQCOXGC5 CQCTK1B1 CQCTK1C5 CQCTK2B1 CQCTK2C5 CQCTK3B1 CQCTK3C5 CQCTK4B1 CQCTK4C5 CQCTK5B1 CQCTK5C5 CQCTK6B1 CQCTK6C5 CQCTK9B1 CQCTK9C5 CQCTTEX1
Fix information
Fixed component name
COMMON COLLECTO
Fixed component ID
5639OLC00
Applicable component levels
R110 PSY UI75916
UP21/06/22 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Type":"MASTER","Line of Business":{"code":"","label":""},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":""},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]
Document Information
Modified date:
03 July 2021