Error description
Dates like 2021-01-00 are not recognized as having an invalid day.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 with programs * * that use the TEST-FORMATTED-DATETIME * * intrinsic function. * **************************************************************** * PROBLEM DESCRIPTION: Intrinsic function * * TEST-FORMATTED-DATETIME * * does not recognize a zero in the day * * field as invalid input. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Intrinsic function TEST-FORMATTED-DATETIME does not recognize a zero in the day field as invalid input. For example, if the following input is provided TEST-FORMATTED-DATETIME('YYYYMMDD', '20210300'), it should return a value of 8, indicating the 8th character is erroneous. Prior to the fix, call to this function with the above input returns 0 indicating the date value is valid when it is not. COB0603T/K
Problem conclusion
The TEST-FORMATTED-DATETIME processing in the COBOL Runtime has been corrected. With the correction, calls to function TEST-FORMATTED-DATETIME with inputs that contain date values with a zero in the day field no longer return a 0 value.
Temporary fix
Comments
APAR Information
APAR number
PH34381
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7C0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-10
Closed date
2021-03-23
Last modified date
2021-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZBALCT IGZCER4 IGZCEV4 IGZCMGEN IGZCMGUE IGZEDCCT IGZIBMCT IGZIGZCT IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.