A fix is available
APAR status
Closed as program error.
Error description
ABENDS0C4 IQCQMR30 at x'942' which causes IMS region to fail. QCF batch job doing BROWSE was running at the time of the S0C4. It was attempting to return an error code, but caused an abend instead.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Queue Control Facility for z/OS * * Version 3 Release 2 (FMID=H0GN320) users. * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C4 IQCQMR30 at x'942' which * * causes IMS region to fail. QCF batch * * job doing BROWSE was running at the * * time of the S0C4. It was attempting to * * return an error code, but caused an * * abend instead. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** An IMS 0C4 Abend was experienced due to a problem in QCF checking of the message length after encountering an error during processing of the second through the nth record of a multi-record message in the local queues.
Problem conclusion
QCF has been changed to return an error code to the caller without ABEND in the IMS control region.
Temporary fix
Comments
APAR Information
APAR number
PH33766
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-25
Closed date
2021-01-29
Last modified date
2021-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI73677
Modules/Macros
IQCQMR3E IQCQMR3F
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI73677
UP21/01/30 P F101 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320"}]
Document Information
Modified date:
02 February 2021