A fix is available
APAR status
Closed as program error.
Error description
An s0c1 exception may occur when a paragraph that is executed as part of a PERFORM statement attempts to return to the statement following the PERFORM statement.
Local fix
Compile with OPT(1)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling * * programs at OPT(1|2) that contain two or * * more PERFORM UNTIL or PERFORM VARYING loops * * PERFORMing the same paragraph or section, * * where the PERFORM statements are the last * * statements in WHEN clauses of an EVALUATE * * statement. * **************************************************************** * PROBLEM DESCRIPTION: Program abends with S0C1. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler incorrectly removed code that stored the address of the next instruction following a PERFORM statement. At the end of a paragraph or section that is PERFORMed, the program would branch to an incorrect address, either jumping to the wrong place in the program or outside of the program. Branching outside the program could result in trying to execute code at an invalid address, causing the S0C1.
Problem conclusion
The compiler was fixed to not remove code that stored the address of the next instruction following a PERFORM statement.
Temporary fix
Comments
APAR Information
APAR number
PH33224
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-11
Closed date
2021-01-22
Last modified date
2021-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYMSGXT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI73593
UP21/01/28 P F101
R631 PSY UI73594
UP21/01/28 P F101
R632 PSY UI73595
UP21/01/28 P F101
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: