APAR status

  • Closed as program error.

Error description

  • When compiling with OPT(1) or OPT(2), compiler terminates with
    following messages:
    
    IGYAS5125-U   The compilation was terminated due to a compiler
    error in phase id:  "IGYCASMB".
    IGYAS5295-U   The compilation failed due to an internal error
    detected in the compiler back-end.  The error code was 267.
    

Local fix

  • Use OPT(0)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling     *
    *                 programs at OPT(1|2) that have multiple      *
    *                 PERFORM statements PERFORMing a              *
    *                 paragraph or section.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abend with message             *
    *                      MSGIGYAS5125-U The compilation          *
    *                      was terminated due to a compiler error  *
    *                      in phase id: "IGYCASMB".                *
    *                      IGYAS5295-U The compilation             *
    *                      failed due to an internal error         *
    *                      detected in the compiler back-end.      *
    *                      The error code was 267.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The compiler's internal state was incorrect before inlining
    PERFORMed paragraphs or sections.
    The compiler aborted when the incorrect internal state was
    detected.
    

Problem conclusion

  • The compiler was fixed to have the correct internal state before
    inlining PERFORMed paragraphs or sections.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH31471

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-11-10

  • Closed date

    2020-11-23

  • Last modified date

    2020-12-01

  • APAR is sysrouted FROM one or more of the following:

    PH31176

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYMSGXT
    IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI72712

       UP20/11/28 P F011

  • R631 PSY UI72713

       UP20/11/28 P F011

  • R632 PSY UI72714

       UP20/11/28 P F011

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023