A fix is available
APAR status
Closed as program error.
Error description
In V6.3, the addition of the "AS FIXED LENGTH" in the USING phrase causes a problem when "AS" is used as a data item. Because "AS" is not considered a reserved word, the compiler is being fixed to properly recognize "AS FIXED LENGTH" and not get hung up on "AS".
Local fix
Change the data item "AS" to another name.
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Enterprise COBOL for z/OS 6.3 * * compiler whose COBOL programs contain * * data items with the name "AS" where the * * data item is used on a USING phrase * * of the COBOL CALL statement. * * For example: * * CALL 'program' USING AS * **************************************************************** * PROBLEM DESCRIPTION: The compiler terminates with severe * * error message IGYPS0088-S. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** An internal compiler problem causes the compiler to improperly issue message IGYPS0088-S when a data item with the name "AS" is specified on the USING phrase of the CALL statement.
Problem conclusion
The internal compiler problem was fixed.
Temporary fix
Comments
APAR Information
APAR number
PH31045
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-28
Closed date
2020-11-23
Last modified date
2020-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYMSGXT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI72712
UP20/11/28 P F011
R631 PSY UI72713
UP20/11/28 P F011
R632 PSY UI72714
UP20/11/28 P F011
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: