IBM Support

PH30556: CPSM AICA SEEN IN TOPOLOGY WARM RESTART PROCESSING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You may see the following messages in your CMAS, accompanied by
    an SVC dump:
    
    EYUXL0905E applid AICA IN XCLA, OFFSET 00000678
    EYUXL0905E INTC=0079 ILC=2 TXCP=6E8C9800 SCODE=S???? TRAN=XLEV
      TASK=0012345
    EYUXL0905E METHODS=XCLA,TIW2,TIML,XLBI,XLEV
    
    EYUTI0003E applid TOPOLOGY INITIALIZATION FAILED.
    
    The dump title would look something like this:
    
    EYU9XLRV DUMP,applid,cmas,sysid,CMAS,XLEV,0012345,AICA,
      EYU0XCLA,mm/dd/yyyy,hh:mm:ss
    
    This APAR being raised to add points in the topology process
    that yields back to the QR TCB to avoid the possibility of an
    AICA.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM users.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: While performing a CPSM CMAS WARM       *
    *                      restart, a CMAS issues message          *
    *                      EYUXL0905E reporting an AICA abend,     *
    *                      where method TIW2 is included in the    *
    *                      method call stack. Subsequently, the    *
    *                      CMAS issues:                            *
    *                      EYUTI0003E applid Topology              *
    *                                 Initialization Failed.       *
    ****************************************************************
    * RECOMMENDATION: PH30556 affects CMAS regions performing      *
    *                 a WARM CMAS restart, and will take effect    *
    *                 from the next restart. The restarts do not   *
    *                 need to occur at the same time.              *
    ****************************************************************
    A CMAS is performing a CPSM WARM CMAS restart. The CMAS is
    reconnecting to existing data spaces. During the Topology warm
    restart process, the topology data cache must be re-initialised.
    Data is temporarily held in a queue, then new cache list
    structures are created in the topology data cache. For a
    suitably large CICSplex, the time taken to read from the queue
    structure and write to the new cache list structure may exceed
    the CMAS region runaway ( ICVR ) value. If this happens, an
    AICA abend will occur, and topology initialisation will fail.
    The CMAS address space will terminate after message
    EYUXL0112E applid CMAS initialization failed
    
    Additional Keywords: TOPWCDTR_QTOKEN EXCPTOPI
    

Problem conclusion

  • EYU0TIW2 has been updated to issue a suspend if needed to
    prevent the system ICVR time from being reached.
    Additionally, the process of adding records to the new cache
    list has been made more efficient to reduce the likelihood
    that the ICVR limit is reached.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH30556

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    00M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-14

  • Closed date

    2021-01-06

  • Last modified date

    2021-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI73352 UI73353 UI73354 UI73355

Modules/Macros

  • EYU0TIW2 EYU0TIWS
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R00M PSY UI73355

       UP21/01/09 P F101

  • R10M PSY UI73354

       UP21/01/08 P F101

  • R20M PSY UI73353

       UP21/01/08 P F101

  • R30M PSY UI73352

       UP21/01/08 P F101

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3"}]

Document Information

Modified date:
02 February 2021