IBM Support

PH30129: DYNAMIC RUNNER V1.0.3 - ABEND 0C4 IN BZUBATCH WHILE EXECUTING RUNNER PROGRAM BZURUN

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When executing a generated zUnit test case using Dynamic Test
    Runner v1.0.3 (BZURUN), the execution unit fails with abend 0C4
    in program BZUBATCH.
    
    09.15.48 JOB07067  +BZUPB01W USER PROGRAM PGMW003 /  IS NOT
    ELIGIBLE FOR STUBBING OR PARAMETER COLLECTION
    09.15.48 JOB07067  +BZUPB02W F1=00000021 F2=23C1D3D3
    09.15.48 JOB07067  IEA995I SYMPTOM DUMP OUTPUT  710
       710             SYSTEM COMPLETION CODE=0C4  REASON
    CODE=00000010
       710              TIME=09.15.48  SEQ=04338  CPU=0000
    ASID=007D
       710              PSW AT TIME OF ERROR  078D0000   9F888AD6
    ILC 6  INTC 10
       710                ACTIVE MODULE
    ADDRESS=00000000_1F887000  OFFSET=00001AD6
       710                NAME=BZUBATCH
       710                DATA AT PSW  1F888AD0 - D2053244  B580D203
    D0886000
       710                AR/GR 0: 00001FFF/00010000_1F804D1A   1:
    00000000/00000000_9F8B5010
       710                      2: 00000000/00000000_1F878050   3:
    00000000/00000000_1F804AD8
       710                      4: 00000000/00000000_1F804B6C   5:
    00000000/00000000_00000003
       710                      6: 00000000/00000000_BF16A0D6   7:
    00000000/00000000_00000000
       710                      8: 00000000/00000000_C2E9E4C1   9:
    00000000/00000000_1F888000
       710                      A: 00000000/00000000_1F878DF8   B:
    00000000/00000000_1F8888A8
       710                      C: 00000000/00000000_09DD4758   D:
    00000000/00000000_1F878B98
       710                      E: 00000000/00000000_9F8B5024   F:
    00000000/7F6E5C80_1F878358
       710              END OF SYMPTOM DUMP
    
    
    JOB RCNJOB1         STEP REPLAY          TIME 091548   DATE
    20279    ID = 000    CPUID = 0007BD983906   PAGE 00000001
    COMPLETION CODE      SYSTEM = 0C4      REASON CODE = 00000010
    
      PSW AT ENTRY TO ABEND   078D0000  9F888AD6  ILC  06  INTC
    0010
    PSW MODULE     ADDRESS = 00000000_1F887000  OFFSET = 00001AD6
    NAME=BZUBATCH
    

Local fix

  • The problem can be worked around by compiling the zUnit
    generated test cases with COBOL 5.x or higher
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 01.Users recording older COBOL programs      *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01.Abend 0C4 in BZUBATCH when recording *
    *                        older COBOL programs                  *
    ****************************************************************
    01.Abend 0C4 in Dynamic Test Runner BZUBATCH while recording
       older COBOL programs, when an attempt was made to determine
       the interface was attempted.
    

Problem conclusion

  • 01.The code to determine the language type for the exit point
       was not processing the older COBOL LE control block properly
       and this caused the abend. The software has been fixed to
       detect these older LE control blocks.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH30129

  • Reported component name

    VIRT TEST PLTFM

  • Reported component ID

    5724T0763

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-10-06

  • Closed date

    2020-12-10

  • Last modified date

    2021-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • BZU2EXEC BZU2LAYR BZU2THIN BZU2TLYR BZU3ALOC BZU6DDEF BZUADSMF
    BZUAINIT BZUAIP2  BZUAIPI  BZUAIPS  BZUAIPX  BZUALLOC BZUAPIPI
    BZUAPRC2 BZUAPRCA BZUAPRCD BZUAPRCX BZUAPRH@ BZUAPRS@ BZUARRS@
    BZUARSMF BZUARST0 BZUARST1 BZUARST2 BZUARST3 BZUARST4 BZUARST5
    BZUARST6 BZUARST7 BZUARST8 BZUARST9 BZUASSRT BZUASTB0 BZUASTB1
    BZUASTB2 BZUASTB3 BZUASTB4 BZUASTB5 BZUASTB6 BZUASTB7 BZUASTB8
    BZUASTB9 BZUASTC0 BZUASTC1 BZUASTC2 BZUASTC3 BZUASTC4 BZUASTC5
    BZUASTC6 BZUASTC7 BZUASTC8 BZUASTC9 BZUASTMD BZUASTMP BZUASTUB
    BZUASTUC BZUAVRDT BZUBATCH BZUBCON@ BZUBCP   BZUBDSC@ BZUBSRV@
    BZUCBCBL BZUCBPL1 BZUCCDFN BZUCCINT BZUCCOLL BZUCDEFN BZUCF410
    BZUCF420 BZUCF510 BZUCF520 BZUCF530 BZUCF540 BZUCF550 BZUCF560
    BZUCI410 BZUCI420 BZUCI510 BZUCI520 BZUCI530 BZUCI540 BZUCI550
    BZUCI560 BZUCICPT BZUCICSA BZUCICSN BZUCICSS BZUCICST BZUCICSW
    BZUCIDFN BZUCIDRI BZUCIDRP BZUCIDRR BZUCIDRS BZUCIDRT BZUCO410
    BZUCO420 BZUCO510 BZUCO520 BZUCO530 BZUCO540 BZUCO550 BZUCO560
    BZUCPLTI BZUCPLTS BZUCPLTT BZUCSD   BZUCSTUB BZUDB2ST BZUDCP
    BZUDLAYR BZUDTHIN BZUDTLYR BZUDYNAL BZUECP   BZUESPIE BZUESPR@
    BZUESTAE BZUGTARG BZUGTMEM BZUHFIO@ BZUHFIOH BZUHFIOP BZUHPRN@
    BZUII410 BZUII420 BZUII510 BZUII520 BZUII530 BZUII540 BZUII550
    BZUII560 BZUIMSSB BZUIMSSE BZUIMSTR BZUIMSVN BZUIMSVR BZUINCL
    BZUIO410 BZUIO420 BZUIO510 BZUIO520 BZUIO530 BZUIO540 BZUIO550
    BZUIO560 BZUISVI0 BZUITERC BZUITERP BZUJFIOH BZUJFIOP BZUKFIO@
    BZUKFIOH BZUKFIOP BZULCEE  BZULDB2  BZULEOPT BZULFIOH BZULFIOP
    BZULIMS  BZULLE   BZULMQ   BZUMCP   BZUMSGEN BZUPBCP  BZUPBMP
    BZUPDB2  BZUPDLI  BZUPLAY  BZUPPLAY BZUPRH00 BZUPRH0@ BZURI410
    BZURI420 BZURI510 BZURI520 BZURI530 BZURI540 BZURI550 BZURI560
    BZURO410 BZURO420 BZURO510 BZURO520 BZURO530 BZURO540 BZURO550
    BZURO560 BZURUN   BZUSCFG  BZUSETUP BZUSLAYR BZUSTLYR BZUSUDSN
    BZUSYSIN BZUTRACE BZUUFIOH BZUUFIOP BZUUMODC BZUUMODD BZUUMODI
    BZUUMODL BZUVERS  BZUVFIOH BZUVFIOP BZUVSAM  BZUWFIOH BZUWFIOP
    BZUXC410 BZUXC420 BZUXC510 BZUXC520 BZUXC530 BZUXC540 BZUXC550
    BZUXC560 BZUXCOLL BZUZFIO@ BZUZFIOH BZUZFIOP
    

Fix information

  • Fixed component name

    VIRT TEST PLTFM

  • Fixed component ID

    5724T0763

Applicable component levels

  • R100 PSY UI72911

       UP20/12/12 P F012

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"100"}]

Document Information

Modified date:
05 January 2021