A fix is available
APAR status
Closed as program error.
Error description
When executing a generated zUnit test case using Dynamic Test Runner v1.0.3 (BZURUN), the execution unit fails with abend 0C4 in program BZUBATCH. 09.15.48 JOB07067 +BZUPB01W USER PROGRAM PGMW003 / IS NOT ELIGIBLE FOR STUBBING OR PARAMETER COLLECTION 09.15.48 JOB07067 +BZUPB02W F1=00000021 F2=23C1D3D3 09.15.48 JOB07067 IEA995I SYMPTOM DUMP OUTPUT 710 710 SYSTEM COMPLETION CODE=0C4 REASON CODE=00000010 710 TIME=09.15.48 SEQ=04338 CPU=0000 ASID=007D 710 PSW AT TIME OF ERROR 078D0000 9F888AD6 ILC 6 INTC 10 710 ACTIVE MODULE ADDRESS=00000000_1F887000 OFFSET=00001AD6 710 NAME=BZUBATCH 710 DATA AT PSW 1F888AD0 - D2053244 B580D203 D0886000 710 AR/GR 0: 00001FFF/00010000_1F804D1A 1: 00000000/00000000_9F8B5010 710 2: 00000000/00000000_1F878050 3: 00000000/00000000_1F804AD8 710 4: 00000000/00000000_1F804B6C 5: 00000000/00000000_00000003 710 6: 00000000/00000000_BF16A0D6 7: 00000000/00000000_00000000 710 8: 00000000/00000000_C2E9E4C1 9: 00000000/00000000_1F888000 710 A: 00000000/00000000_1F878DF8 B: 00000000/00000000_1F8888A8 710 C: 00000000/00000000_09DD4758 D: 00000000/00000000_1F878B98 710 E: 00000000/00000000_9F8B5024 F: 00000000/7F6E5C80_1F878358 710 END OF SYMPTOM DUMP JOB RCNJOB1 STEP REPLAY TIME 091548 DATE 20279 ID = 000 CPUID = 0007BD983906 PAGE 00000001 COMPLETION CODE SYSTEM = 0C4 REASON CODE = 00000010 PSW AT ENTRY TO ABEND 078D0000 9F888AD6 ILC 06 INTC 0010 PSW MODULE ADDRESS = 00000000_1F887000 OFFSET = 00001AD6 NAME=BZUBATCH
Local fix
The problem can be worked around by compiling the zUnit generated test cases with COBOL 5.x or higher
Problem summary
**************************************************************** * USERS AFFECTED: 01.Users recording older COBOL programs * **************************************************************** * PROBLEM DESCRIPTION: 01.Abend 0C4 in BZUBATCH when recording * * older COBOL programs * **************************************************************** 01.Abend 0C4 in Dynamic Test Runner BZUBATCH while recording older COBOL programs, when an attempt was made to determine the interface was attempted.
Problem conclusion
01.The code to determine the language type for the exit point was not processing the older COBOL LE control block properly and this caused the abend. The software has been fixed to detect these older LE control blocks.
Temporary fix
Comments
APAR Information
APAR number
PH30129
Reported component name
VIRT TEST PLTFM
Reported component ID
5724T0763
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-06
Closed date
2020-12-10
Last modified date
2021-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
BZU2EXEC BZU2LAYR BZU2THIN BZU2TLYR BZU3ALOC BZU6DDEF BZUADSMF BZUAINIT BZUAIP2 BZUAIPI BZUAIPS BZUAIPX BZUALLOC BZUAPIPI BZUAPRC2 BZUAPRCA BZUAPRCD BZUAPRCX BZUAPRH@ BZUAPRS@ BZUARRS@ BZUARSMF BZUARST0 BZUARST1 BZUARST2 BZUARST3 BZUARST4 BZUARST5 BZUARST6 BZUARST7 BZUARST8 BZUARST9 BZUASSRT BZUASTB0 BZUASTB1 BZUASTB2 BZUASTB3 BZUASTB4 BZUASTB5 BZUASTB6 BZUASTB7 BZUASTB8 BZUASTB9 BZUASTC0 BZUASTC1 BZUASTC2 BZUASTC3 BZUASTC4 BZUASTC5 BZUASTC6 BZUASTC7 BZUASTC8 BZUASTC9 BZUASTMD BZUASTMP BZUASTUB BZUASTUC BZUAVRDT BZUBATCH BZUBCON@ BZUBCP BZUBDSC@ BZUBSRV@ BZUCBCBL BZUCBPL1 BZUCCDFN BZUCCINT BZUCCOLL BZUCDEFN BZUCF410 BZUCF420 BZUCF510 BZUCF520 BZUCF530 BZUCF540 BZUCF550 BZUCF560 BZUCI410 BZUCI420 BZUCI510 BZUCI520 BZUCI530 BZUCI540 BZUCI550 BZUCI560 BZUCICPT BZUCICSA BZUCICSN BZUCICSS BZUCICST BZUCICSW BZUCIDFN BZUCIDRI BZUCIDRP BZUCIDRR BZUCIDRS BZUCIDRT BZUCO410 BZUCO420 BZUCO510 BZUCO520 BZUCO530 BZUCO540 BZUCO550 BZUCO560 BZUCPLTI BZUCPLTS BZUCPLTT BZUCSD BZUCSTUB BZUDB2ST BZUDCP BZUDLAYR BZUDTHIN BZUDTLYR BZUDYNAL BZUECP BZUESPIE BZUESPR@ BZUESTAE BZUGTARG BZUGTMEM BZUHFIO@ BZUHFIOH BZUHFIOP BZUHPRN@ BZUII410 BZUII420 BZUII510 BZUII520 BZUII530 BZUII540 BZUII550 BZUII560 BZUIMSSB BZUIMSSE BZUIMSTR BZUIMSVN BZUIMSVR BZUINCL BZUIO410 BZUIO420 BZUIO510 BZUIO520 BZUIO530 BZUIO540 BZUIO550 BZUIO560 BZUISVI0 BZUITERC BZUITERP BZUJFIOH BZUJFIOP BZUKFIO@ BZUKFIOH BZUKFIOP BZULCEE BZULDB2 BZULEOPT BZULFIOH BZULFIOP BZULIMS BZULLE BZULMQ BZUMCP BZUMSGEN BZUPBCP BZUPBMP BZUPDB2 BZUPDLI BZUPLAY BZUPPLAY BZUPRH00 BZUPRH0@ BZURI410 BZURI420 BZURI510 BZURI520 BZURI530 BZURI540 BZURI550 BZURI560 BZURO410 BZURO420 BZURO510 BZURO520 BZURO530 BZURO540 BZURO550 BZURO560 BZURUN BZUSCFG BZUSETUP BZUSLAYR BZUSTLYR BZUSUDSN BZUSYSIN BZUTRACE BZUUFIOH BZUUFIOP BZUUMODC BZUUMODD BZUUMODI BZUUMODL BZUVERS BZUVFIOH BZUVFIOP BZUVSAM BZUWFIOH BZUWFIOP BZUXC410 BZUXC420 BZUXC510 BZUXC520 BZUXC530 BZUXC540 BZUXC550 BZUXC560 BZUXCOLL BZUZFIO@ BZUZFIOH BZUZFIOP
Fix information
Fixed component name
VIRT TEST PLTFM
Fixed component ID
5724T0763
Applicable component levels
R100 PSY UI72911
UP20/12/12 P F012
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"100"}]
Document Information
Modified date:
05 January 2021