APAR status
Closed as program error.
Error description
With IDz v14.2.3 Running a zUnit testcase fails with abend U4087 and error CEE0802C Heap storage control information was damaged. CEE0802C Heap storage control information was damaged. The problem happens for COBOL programs containing REDEFINES where the size of the base data item is smaller than the size of the redefined item. When you start a Generate test case from zUnit, the test generation is complete with the correct Property group association. The load module (static link) is created The test case build is complete When you choose to continue running that test case, the Problem occurred with â z/OS Automated Unit Testing Framework (Zunit) is shown: CRRZI0075E The submitted job has ended abnormally JOB09415 terminated with completion code abend U4087
Local fix
Problem summary
When testing zUnit with Test Runner (AZUTSTRN) on IDz V14.2.3, running a zUnit testcase fails with abend U4087 and error CEE0802C Heap storage control information was damaged. This problem occurs when multiple data items are defined with REDEFINES in the parameters of the program under test, and the data items to be REDEFINES are larger than the size of the base data items.
Problem conclusion
This issue has been resolved.
Temporary fix
Comments
APAR Information
APAR number
PH30042
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
E20
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-30
Closed date
2020-12-04
Last modified date
2020-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Line of Business":{"code":"LOB17","label":"Mainframe TPS"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSQ2R2","label":"Rational Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E20"}]
Document Information
Modified date:
05 December 2020