Error description
we want to copy some groups whose names begin with XCIC720 to groups with name YCIC720. We do this by means of utility DFHCSDUP and command COPY GROUP(XCIC720*) TO(YCIC720*). Doing this, we get a RC of 8 and message DFH5260 E LENGTH OF 'TO' SUFFIX MUST BE EQUAL TO LENGTH OF 'GROUP' SUFFIX. When using command COPY GROUP(XCIC72*) TO(YCIC72*) everything works fine.
Local fix
fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: Using DFHCSDUP to copy generic groups * * may give message DFH5260 E LENGTH OF * * 'TO' SUFFIX MUST BE EQUAL TO LENGTH OF * * 'GROUP' SUFFIX. * **************************************************************** When using DFHCSDUP to copy generic groups, if the generic indicator (*) is in position 8 of the group name then DFHCSDUP will fail with DFH5260 E LENGTH OF 'TO' SUFFIX MUST BE EQUAL TO LENGTH OF 'GROUP' SUFFIX, because the code incorrectly calculates the length of the 'TO' and 'GROUP' suffixes. keywords: msgDFH5260E 5260E
Problem conclusion
DFHCUCOG has been changed to correctly calculate the 'TO' suffix and the 'GROUP' suffix when the generic indicator is in position 8 of the group name,
Temporary fix
Comments
APAR Information
APAR number
PH29678
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-21
Closed date
2020-10-15
Last modified date
2020-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI72089 UI72090
Modules/Macros
DFHCUCOG
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
Fix is available