A fix is available
APAR status
Closed as program error.
Error description
Compile-time performance with the TEST option is noticeably slower compared to COBOL 6.2 and below in some circumstances.
Local fix
Compile without TEST
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Enterprise COBOL 6.2 compiler * * whose COBOL programs are compiled with the * * TEST option. * **************************************************************** * PROBLEM DESCRIPTION: In some circumstances users may * * experience prolonged compile-time * * performance. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Due to recent enhancements in the TEST option the compile-time performance of the compiler is slower than expected in some circumstances.
Problem conclusion
The compiler was updated to improve the compile-time performance when using the TEST option.
Temporary fix
Comments
APAR Information
APAR number
PH28555
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-08-17
Closed date
2020-08-18
Last modified date
2020-09-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8CICS IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI71111
UP20/08/29 P F008
R621 PSY UI71112
UP20/08/29 P F008
R622 PSY UI71113
UP20/08/29 P F008
R62H PSY UI71114
UP20/08/29 P F008
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023