Error description

  • IMS HP Image Copy issues incorrect message FABJ3703E when the
    process terminates ABEND U3958.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for      *
    *                 z/OS Version 4 Release 2 users               *
    *                 ( FMID=H1J0420 ).                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS HP Image Copy issues incorrect      *
    *                      error message FABJ3703E                 *
    *                      ( MSGFABJ3703E ) when the process       *
    *                      terminates ABEND U3958 ( ABENDU3958 ).  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The error handing process of IMS HP Image Copy sets the
    incorrect message number when the process detects the error
    reason of ABEND U3958 ( ABENDU3958 ).
    

Problem conclusion

  • After applying this maintenance, the correct message FABJ3958E
    ( MSGFABJ3958E ) is issued when the process terminates ABEND
    U3958 ( ABENDU3958 ).
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH27931

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-29

  • Closed date

    2020-08-17

  • Last modified date

    2020-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI71088

Modules/Macros

  • FABJRCH2 FABJRCH3 FABJRCH4 FABJRCH5 FABJRCH9 FABJRCHA FABJRCHB
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI71088

       UP20/08/19 P F008

Fix is available