A fix is available
APAR status
Closed as program error.
Error description
Modify setting of LDA to avoid conflicting values causing resulting in alerts.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 1. IBM Security Guardium S-TAP for * * Db2 on z/OS * * 2. IBM Db2 Query Monitor z/OS * * users of components * * - CQM Data Collector * * - Current Activity * * - Summaries * * - Profiles * * - CAE Server * **************************************************************** * PROBLEM DESCRIPTION: The IBM Health Checker for z/OS and * * PFA alert messages HZS0003E and * * AIRH222E may unexpectedly appear, * * predicting Private Storage Exhaustion * * for the Query Monitor or Guardium * * started task. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** The Common Collector lifts the extended user region limit at initialization time to be able to use all available storage. It may cause IBM Health Checker for z/OS and PFA alert messages HZS0003E and AIRH222E issued prematurely due to the requested extended user region capacity left unchanged.
Problem conclusion
Code changed to set requested extended user region capacity to the 0.875 of the extended user region limit. Set REGION=0M in the started task JCL or ignore alerts.
Temporary fix
Comments
APAR Information
APAR number
PH27911
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-07-28
Closed date
2020-08-06
Last modified date
2020-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI70935
Modules/Macros
CQM#INIX CQM#PCIX CQMBLOB CQMCPXPT CQMJCC CQMMPGEX CQMUPXPT
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI70935
UP20/08/13 P F008
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"3.3.0"}]
Document Information
Modified date: