Error description
ABEND0E0-29 in IAXCV
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Db2 Query Monitor for z/OS * * Users of IBM Security Guardium S-TAP for Db2 * * on z/OS * **************************************************************** * PROBLEM DESCRIPTION: ABEND0E0-0029 in IAXCV * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** ABEND0E0-0029 in IAXCV due to incorrect non-empty access register.
Problem conclusion
Clear out access registers before calling IARCP64 system macro for memory allocation. Search Keywords: ABEND 0C4-0004 CQCMESC5 DISTRIBUTED THREADS ABEND 0E0-0029 IAXCV
Temporary fix
Comments
APAR Information
APAR number
PH26998
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-30
Closed date
2020-07-24
Last modified date
2020-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQM#BCMX CQM#INIX CQM#PARM CQM#SSMN CQMMEACX CQMMEAPX CQMMEARX CQMMEASX CQMMEBCX CQMMEBPX CQMMEBRX CQMMEBSX CQMMECCX CQMMECPX CQMMECRX CQMMECSX CQMMEMTX CQMMINIX
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI70745
UP20/07/25 P F007 ¢