Error description

  • The Continuous Collector is not setting the initial time
    correctly for the timer loop when COLLECT AFTER 1 MINUTES
    is requested and the start time for the collect is 8, 18, 28,
    38, 48 or 58 minutes past the hour.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IZDS and IZPCA customers running the     *
    *                 Continuous Collector.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Continuous Collector is not         *
    *                      issuing COMMITs resulting in warning    *
    *                      messages in the DB2 log eg:             *
    *                      DSNJ031I -DEC3 DSNJW011 WARNING -       *
    *                      UNCOMMITTED UR 652                      *
    *                      HAS WRITTEN 2250000 LOG RECORDS         *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    This problem only occurs when the Continuous Collector has set
    COMMIT AFTER 1 MINUTES and the collect happens to start on a
    a time boundary where the minutes end in an 8, eg 28, 38 etc.
    In which case the timer is set incorrectly.
    

Problem conclusion

  • The code is changed to set the timer correctly with
    COMMIT AFTER 1 MINUTES when the collect happens to start on a
    a time boundary where the minutes end in an 8, eg 28, 38 etc.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH25023

  • Reported component name

    TDS FOR Z/OS

  • Reported component ID

    569510100

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-05-03

  • Closed date

    2020-05-18

  • Last modified date

    2020-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI69572 UI69573

Modules/Macros

  • DRLPLOPC
    

Fix information

  • Fixed component name

    TDS FOR Z/OS

  • Fixed component ID

    569510100

Applicable component levels

  • R901 PSY UI69573

       UP20/05/20 P F005

  • RC01 PSY UI69572

       UP20/05/20 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 June 2020