A fix is available
APAR status
Closed as program error.
Error description
The Continuous Collector is not setting the initial time correctly for the timer loop when COLLECT AFTER 1 MINUTES is requested and the start time for the collect is 8, 18, 28, 38, 48 or 58 minutes past the hour.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IZDS and IZPCA customers running the * * Continuous Collector. * **************************************************************** * PROBLEM DESCRIPTION: The Continuous Collector is not * * issuing COMMITs resulting in warning * * messages in the DB2 log eg: * * DSNJ031I -DEC3 DSNJW011 WARNING - * * UNCOMMITTED UR 652 * * HAS WRITTEN 2250000 LOG RECORDS * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** This problem only occurs when the Continuous Collector has set COMMIT AFTER 1 MINUTES and the collect happens to start on a a time boundary where the minutes end in an 8, eg 28, 38 etc. In which case the timer is set incorrectly.
Problem conclusion
The code is changed to set the timer correctly with COMMIT AFTER 1 MINUTES when the collect happens to start on a a time boundary where the minutes end in an 8, eg 28, 38 etc.
Temporary fix
Comments
APAR Information
APAR number
PH25023
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-03
Closed date
2020-05-18
Last modified date
2020-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI69572 UI69573
Modules/Macros
DRLPLOPC
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 June 2020