APAR status
Closed as program error.
Error description
In IBM Developer for z/OS (IDz) v14.1.7, some SCLM controlled members can be modified from the Remote Systems or the z/OS Projects view, even though the same members from ISPF cannot be edited. These members do not have an associated SCLM project definition within the scope of the member's associated high level qualifier (HLQ) data set (no <HLQ>.PROJDEFS.LOAD for the member).
Local fix
Problem summary
SCLM ownership of file was only checked for HLQ with PROJDEFS.LOAD indicating SCLM control of HLQ on dataset. SCLM ownership is per member, and can exist outside of the origin HLQ for instance by SCLM promote or by copy.
Problem conclusion
SCLM ownership must be checked per call on a member, and disregard PROJDEFS.LOAD existence as a proof point for needing to check for SCLM control of the member.
Temporary fix
Comments
APAR Information
APAR number
PH24857
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
E10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-04-28
Closed date
2020-08-06
Last modified date
2020-08-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E10","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
27 October 2020