IBM Support

PH24370: MISMATCH BETWEEN OPTIM DIRECTORY AND EXTRACT FILE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error description:
    Customer is performing EXTRACT+CONVERT processing in BATCH.
    He receives the following error message:
     *** ERROR ***        Archive/Extract entry with this name
     exists, use the Batch keyword  REPLACE_ARC_DIR or
     REPLACE_EXT_DIR to override
    
    Customer adds REPLACE_EXT_DIR YES control statement to his job
    and now Optim aborts processing with the following System Error:
    
    IBM InfoSphere Optim System Error Structure - ErrCB
    ErrCB.ID=      ZZZERRCBZZ
    SysRel=        11.7.0
    DB2Rel=        1215(NFM)
    ErrCB.Type=    SYSTEM_ERROR
    ErrCB.AuxInfo=
    ErrCB.Code=    -1
    ErrCB.U.Msg=   MISMATCH BETWEEN OPTIM DIRECTORY AND EXTRACT FILE
    Number of Function Entries=  8
      ErrCB.N(0).Src=     FOPZXFM2 20200228 PH22758D
      ErrCB.N(0).Func=    (002278) XFMOpen
      ErrCB.N(1).Src=     FOPZPRNT 20191022 PH17637D
      ErrCB.N(1).Func=    (000474) XFMPrint
      ErrCB.N(2).Src=     FOPJCON  20191022 PH17637D
      ErrCB.N(2).Func=    (008037) ControlErrorReportPrint
      ErrCB.N(3).Src=     FOPJCON  20191022 PH17637D
      ErrCB.N(3).Func=    (003683) BuildConvertReport
      ErrCB.N(4).Src=     FOPUCRE  20200217 PH21897D
      ErrCB.N(4).Func=    (007420) ConvertExec
      ErrCB.N(5).Src=     FOPUCRE  20200217 PH21897D
      ErrCB.N(5).Func=    (000955) CreateStatement
      ErrCB.N(6).Src=     FOPUMAIN 20190827 PH15292D
      ErrCB.N(6).Func=    (000856) FOPMMUTL_dynamn
      ErrCB.N(7).Src=     FOPMMAIN 20200129 PH20886D
      ErrCB.N(7).Func=    (001072) Main
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Optim users working with EXTRACT+CONVERT     *
    *                 scenarios.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Optim may report SystemError of:        *
    *                      MISMATCH BETWEEN OPTIM DIRECTORY AND    *
    *                      EXTRACT FILE                            *
    ****************************************************************
    Customer attempts to create an EXTRACT file (XF) in BATCH.
    However there is already an XF with specified name in the Optim
    EXTRACT directory.
    The suggested action of adding the REPLACE_EXT_DIR YES control
    statement does not resolve the issue because now Optim ends
    processing with a System Error.
    

Problem conclusion

  • Optim processing correctly reports the presence of an entry for
    this EXTRACT file in the Optim directory. Such entry must have
    been created at a time when customer enabled cataloging of
    EXTRACT files in his option. Later on this option has been
    disabled but EXTRACT file entries have already been created and
    cataloged.
    Optim's suggestion of adding REPLACE_EXT_DIR YES, while correct,
    will not suffice when cataloging of EXTRACT files is not
    enabled. This message will now be enhanced to point this out or
    suggest that the entry be removed manually from the directory.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH24370

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B30

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-04-14

  • Closed date

    2020-04-21

  • Last modified date

    2020-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH24381

Modules/Macros

  • FOP4PMMN FOP9APIM FOPCFPMN FOPCXLIB FOPHSTM  FOPMAIN  FOPMAMAI
    FOPMARCN FOPMCOLA FOPMCOLP FOPMDPRC FOPMDXTR FOPMECMN FOPMMCMN
    FOPMMCMR FOPMMJBS FOPMMUTL FOPMUXIM FOPODPP  FOPOMN   FOPRS10
    FOPRS2   FOPRS3   FOPZFMMN
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB30 PSY UI69130

       UP20/04/23 P F004

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 May 2020