IBM Support

PH24319: TEST (,,,SEPARATE(NODSNAME)), POSIX(ON) GIVES NO LOCAL VARIABLES IN CEEDUMP

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • TEST (,,,SEPARATE(NODSNAME)), POSIX(ON) GIVES NO LOCAL
    VARIABLES IN CEEDUMP
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6R2 and later     *
    *                 releases compiling programs with             *
    *                 SEPARATE(DSNAME) or SEPARATE(NODSNAME)       *
    *                 suboption in TEST(...) and running COBOL     *
    *                 programs with POSIX(ON) LE runtime option.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: When a CEEDUMP is produced, COBOL       *
    *                      Program's 'Local variable' section in   *
    *                      the CEEDUMP output is missing.          *
    *                                                              *
    *                      With PH22618 applied, the following     *
    *                      diagnostic message is additionally      *
    *                      printed in CEEDUMP:                     *
    *                                                              *
    *                       Local Variables:                       *
    *                       ...                                    *
    *                       COBOL variables were inaccessible.     *
    *                       Reason: cannot initialize the debug    *
    *                       file ...                               *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    With POSIX(ON) LE runtime option, COBOL Runtime had a logic
    error when DWARF information was initialized, resulting in
    missing 'Local variable' section.
    
    COB0602T/K COB0603T/K
    

Problem conclusion

  • COBOL Runtime processing for CEEDUMP has been corrected to
    address the error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH24319

  • Reported component name

    LE ENT COBOL LI

  • Reported component ID

    568819812

  • Reported release

    7C0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-04-10

  • Closed date

    2020-07-08

  • Last modified date

    2020-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGZBALCT IGZCEV4  IGZCMGEN IGZCMGJA IGZCMGUE IGZEDCCT IGZIBMCT
    IGZIGZCT IGZLLIBV IGZXAPI  IGZXCDA  IGZXD24  IGZXDMR  IGZXLPIO
    IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG
    IGZXPK2
    

Fix information

  • Fixed component name

    LE ENT COBOL LI

  • Fixed component ID

    568819812

Applicable component levels

  • R7A0 PSY UI70444

       UP20/07/24 P F007

  • R7B0 PSY UI70448

       UP20/07/24 P F007

  • R7BJ PSY UI70449

       UP20/07/24 P F007

  • R7C0 PSY UI70450

       UP20/07/24 P F007

  • R7CJ PSY UI70451

       UP20/07/24 P F007

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7C0","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]

Document Information

Modified date: