A fix is available
APAR status
Closed as program error.
Error description
Compiler abend with message MSG IGYCB7104-U Assertion failed at ../../trwcode/optimizer/analyses/COBOL UseBeforeSet.cpp:896: foundSavedInfo
Local fix
Correct the program so PERFORMs aren't called recursively, or compile with NOINITCHECK
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL compiling programs * * with INITCHECK where one or more paragraphs * * or sections are only reachable from PERFORM * * statements within other sections or * * paragraphs that are recursively PERFORMed. * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with message * * MSGIGYCB7104-U Assertion failed at * * ../../trwcode/optimizer/analyses/COBOL * * UseBeforeSet.cpp:896: foundSavedInfo * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler was unable to determine which data items were initialized on entry to a recursively-PERFORMed section or paragraph. The compiler chose to terminate rather than continue.
Problem conclusion
The compiler was fixed to continue without initialization information for a recursively-PERFORMed section or paragraph. As data items referenced in that section might be initialized outside the section, the compiler conservatively treats all data items in the section or paragraph as initialized.
Temporary fix
Comments
APAR Information
APAR number
PH23531
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-20
Closed date
2020-03-26
Last modified date
2020-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI68641
UP20/04/01 P F003
R631 PSY UI68642
UP20/04/01 P F003
R632 PSY UI68643
UP20/04/01 P F003
R63H PSY UI68644
UP20/04/01 P F003
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023