A fix is available
APAR status
Closed as program error.
Error description
When COBOL programs contain an OBJECT or FACTORY paragraph outside of a CLASS definition, it is possible for the compiler program to issue the terminating message.
Local fix
*
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Enterprise COBOL 6.3 compiler * * whose COBOL programs contain an OBJECT or * * FACTORY paragraph outside of a CLASS * * definition. * **************************************************************** * PROBLEM DESCRIPTION: When the above conditions are met it * * is possible for the compiler program * * to issue the following terminating * * error message: * * * * IGYLS5125-U The compilation was * * terminated due to a compiler error in * * phase id: "IGYCLSTR". * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** In some cases when a COBOL program contains an OBJECT or FACTORY paragraph that is not contained within a CLASS definition, it is possible that the compiler encounters an unrecoverable terminating error that results in the above mentioned error message, which is generally unhelpful to users.
Problem conclusion
The compiler was fixed to eliminate the unrecoverable error. The following error message will be issued: IGYDS1502-S A FACTORY paragraph was found outside a class definition. The source code following this paragraph was processed as a FACTORY defintion.
Temporary fix
Comments
APAR Information
APAR number
PH23527
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-20
Closed date
2020-03-26
Last modified date
2020-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI68641
UP20/04/01 P F003
R631 PSY UI68642
UP20/04/01 P F003
R632 PSY UI68643
UP20/04/01 P F003
R63H PSY UI68644
UP20/04/01 P F003
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: