APAR status
Closed as program error.
Error description
After enabling the requestTiming-1.0 feature SDSF command F <server_name>,DISPLAY,WORK is rejected: see https://github.ibm.com/was-liberty/WS-CD-Open/issues/20374
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server Liberty - Install V8 and above * **************************************************************** * PROBLEM DESCRIPTION: Install Liberty 19.0.0.10 and update it * * to 20.0.0.2. The auto feature * * zosConsoleCommandDisplayWork-1.0 is not * * installed. * **************************************************************** * RECOMMENDATION: * **************************************************************** The root cause of the update failure is the Liberty Installation Manager bundle com.ibm.was.liberty.asset.selection_18.0.3.20190917_1909.jar. Both 19.0.0.10 and 20.0.0.2 used the same version and time stamp but 20.0.0.2 includes a fix of feature resolver which gets the auto feature zosConsoleCommandDisplayWork-1.0. However, when Installation Manager updates 19.0.0.10 to 20.0.0.2 it still using the bundle from 19.0.0.10 without the fix instead of the bundle in 20.0.0.2.
Problem conclusion
The fix is to update the bundle time stamp to a new version. The fix for this APAR is currently targeted for inclusion in fix pack 20.0.0.4 Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PH23517
Reported component name
LIBERTY PROF -
Reported component ID
5655W6514
Reported release
CD0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-20
Closed date
2020-03-20
Last modified date
2020-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LIBERTY PROF -
Fixed component ID
5655W6514
Applicable component levels
RCD0 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"CD0"}]
Document Information
Modified date: