A fix is available
APAR status
Closed as program error.
Error description
You have CMAS connectivity issues and your CPSM CMAS issues a EYUCL0113E message. The format of the message is . EYUCL0113E date time applid {Receive Link Task | Send Link Task} terminated abnormally for {CPI-C | MRO | CPI-C Network | MRO Network | LU6.2} connection with {CMAS | RMAS} nodename, TaskID(taskid). . In that message, the 'nodename' insert is supposed to be the name of a CMAS or RMAS. But instead, you may see something like: . EYUCL0113E mycmas Receive Link Task terminated abnormally for CPI-C Network connection with CMAS G·» /, TaskID(12345). . Notice the garbled CMAS name, which could be either blanks or any random characters. This is incorrect. . This APAR is being opened to correct the invalid CMAS name in the EYUCL0113E message.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM users. * **************************************************************** * PROBLEM DESCRIPTION: When the connection between two CMAS * * regions terminates unexpectedly, * * message EYUCL0113E will be issued * * reporting the failure. * * EYUCL0113E date time applid * * {Receive Link Task | Send Link Task} * * terminated abnormally for * * {CPI-C | MRO | CPI-C Network | * * MRO Network | LU6.2} * * connection with {CMAS | RMAS} * * nodename, TaskID(taskid). * * In some scenarios where the connection * * was never fully formed, this message * * may have missing, or incorrect, * * characters in place of the identifier * * for the first speaker CMAS. * **************************************************************** * RECOMMENDATION: After applying the PTF which resolves * * PH23393 all CMAS regions should be restarted * * to activate the fix. Note that the restarts * * do not need to occur at the same time. * **************************************************************** In connections between two CMAS regions, the CMAS with the lower sysid is designated the "first speaker" CMAS, and is responsible for initiating the connection. The first speaker will attach a send task, and send a message to the "quiet side" CMAS to attach the receive task. This receive task runs the initial contact transient (ICT). The ICT will dechain a free buffer area, and use this to receive the COMGNNLD packet from the first speaker. This contains information used to continue to instantiate the connection. Before receiving the packet, the CMAS will test whether CMAS communication is still active ( CONN_NO_CONNECT ). In cases where this is false (for example, if this CMAS has been isolated by the maintenance point CMAS) then the receive will never be performed, and message EYUCL0113E will be issued. . EYUCL0113E date time applid Receive Link Task terminated abnormally for {CPI-C Network | MRO Network} connection with CMAS nodename, TaskID(taskid). . The nodename insert in this message would have been populated from the COMGNNLD data, but since this data area was not received into the buffer it is instead populated using residual data.
Problem conclusion
EYU0CLMT and EYU0CMCT, the initial contact transients for MRO and CPI-C CMTCMLNK connections, have been updated to ensure that the COMGNNLD buffer area is cleared prior to use, and that, in cases where the COMGNNLD buffer cannot be received, the nodename of the first speaker CMAS is initialised using data held by CICS in the connection information.
Temporary fix
Comments
APAR Information
APAR number
PH23393
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
000
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-17
Closed date
2020-04-16
Last modified date
2020-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI69039 UI69040 UI69041
Modules/Macros
EYU0CLCT EYU0CLMT
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R00M PSY UI69039
UP20/04/18 P F004
R10M PSY UI69040
UP20/04/17 P F004
R20M PSY UI69041
UP20/04/17 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: