A fix is available
APAR status
Closed as program error.
Error description
The FUNCTION INTEGER-OF-DATE may return incorrect results when the STGOPT compiler option is used for AMODE(64) programs (compiled with the LP(64) compiler option).
Local fix
Compile with NOSTGOPT.
Problem summary
**************************************************************** * USERS AFFECTED: Users of the Enterprise COBOL V6.3 compiler * * running AMODE 64 COBOL programs that use * * INTEGER-OF-DATE or INTEGER-OF-DAY intrinsic * * functions. * **************************************************************** * PROBLEM DESCRIPTION: AMODE 64 COBOL programs that use * * INTEGER-OF-DATE or INTEGER-OF-DAY * * intrinsic functions may encounter * * unexpected behaviour or may ABEND. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Invalid memory is inadvertently accessed in the COBOL runtime due to an error in the compiler generated code when calling COBOL Runtime routines to compute the INTEGER-OF-DATE and INTEGER-OF-DAYS intrinsic functions while the LP(64) compiler option is in effect. COB0603T/K
Problem conclusion
The COBOL runtime was fixed to accept the corrected generated code from the COBOL compiler. In order to obtain this fix, AMODE 64 COBOL programs must be compiled with the COBOL Compiler having APAR PH24829 installed. For AMODE 64 COBOL programs compiled without APAR PH24829, the behaviour would be the same as before (that is, would contain the error described in Problem Description).
Temporary fix
Comments
APAR Information
APAR number
PH22989
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7C0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-05
Closed date
2020-05-20
Last modified date
2020-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI69632 UI69635
Modules/Macros
CELQSG04 CELQV004 IGZQAPI IGZQCDA IGZQINPL
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]
Document Information
Modified date:
14 December 2020