A fix is available
APAR status
Closed as program error.
Error description
When CICS is SHUTDOWN IMMEDIATE, the next CICS restart type is EMERGENCY. Then when CICS restart type is EMERGENCY and RESYNCMEMBER(YES) is specified, CICS requires to reconnect to the previously connected Db2 member. This is because Db2 itself may have INDOUBT UOWs it wishes to let CICS know about, during the connection and resync. The process occurs in this way whether or not there are indoubt UOWs. If the same DB2 member is not available the resync can not take place. . This can cause an issue if restarting CICS on a different LPAR, and the original Db2 subsystem is not available to reconnect to. . DFHSI8440I CICSxxxx Initiating connection to DB2.. DFHDB2037 CICSxxxx .. DB2 subsystem DBR1 is not active. The CICS-DB2 attachment facility is waiting.. DFHSI8443 CICSxxxx Connection to DB2 not completed. Adapter is awaiting initialization of DB2..
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: An emergency restart of CICS always * * attempts to connect to previously * * connected Db2 subsystem. * **************************************************************** In the customers case a CICS region was cancelled, it was connected to Db2 subsystem 'A' using group attach. It did not have any shunted UOWs. This CICS region was then restarted on a different LPAR but still required a connection to Db2 subsystem 'A'. Keywords: msgDFHSI8440I SI8440I msgDFHDB2037 DB2037 msgDFHSI8443 SI8443
Problem conclusion
The CICS Db2 interface has been changed to catalog the MVS system name. On a CICS restart, if it is an emergency then if the MVS is not the same as the CICS was previously started on there is no need to connect to the same Db2. After APPLYing the PTF associated with this APAR a COLD or INITIAL start will be required to update the global catalog's Db2 record.
Temporary fix
Comments
APAR Information
APAR number
PH22731
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-27
Closed date
2020-08-06
Last modified date
2021-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI70929 UI70930 UI70931
Modules/Macros
DFHD2CC DFHD2CM1 DFHD2CO DFHD2D2 DFHD2DUF DFHD2EX1 DFHD2EX2 DFHD2EX3 DFHD2IN1 DFHD2IN2 DFHD2MSB DFHD2RL DFHD2RP DFHD2ST DFHD2STP DFHD2STR DFHD2TM DFHD2TRI DFHDSMT DFHSIB1
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R100 PSY UI70931
UP20/08/07 P F008
R200 PSY UI70930
UP20/08/07 P F008
R300 PSY UI70929
UP20/08/07 P F008