APAR status
Closed as program error.
Error description
Whilest attempting to copy dasd from mainframe using create component from zOS volumes, an 0C4 abend occurred on the IBM Z mainframe. In the system console, the following messages were written/logged: 10.27.01 STC00338 IEA995I SYMPTOM DUMP OUTPUT 064 064 SYSTEM COMPLETION CODE=0C4 REASON CODE=00000010 064 TIME=10.27.01 SEQ=09565 CPU=0000 ASID=0095 064 PSW AT TIME OF ERROR 078D1000 A6B1F25A ILC 4 INTC 10 064 ACTIVE MODULE ADDRESS=00000000_26B1F000 OFFSET=0000025A 064 NAME=FEUSI002 064 DATA AT PSW 26B1F254 - 40005860 40205810 900CA7E5 064 GR 0: 000001EF_00000011 1: 00000004_00000000 064 2: 00000000_26B20000 3: 00000000_26B1C1E8 064 4: 00000000_26B2037C 5: 00000000_74D2596B 064 6: 00000000_40404040 7: 00000000_26B1C340 064 8: 00000000_FFFFFFFD 9: 00000000_66F243BC 064 A: 00000000_00000003 B: 00000000_0000DCF0 064 C: 00000000_A6B1F000 D: 00000000_26B1C0E0 064 E: 00000000_A6B1F262 F: 00000000_00000004 064 END OF SYMPTOM DUMP 10.27.01 STC00338 OPS4200I MESSAGE: '0' 10.27.01 STC00338 BPXP018I THREAD 2757780000000000, IN PROCESS 16781198, ENDED 066 066 WITHOUT BEING UNDUBBED WITH COMPLETION CODE 940C4000 066 , AND REASON CODE 00000010.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * ZD&T Tools users. * **************************************************************** * PROBLEM DESCRIPTION: * * Create component from zOS volumes gives an 0C4 abend * * occurred on the IBM Z mainframe. * **************************************************************** * RECOMMENDATION: * **************************************************************** Extract causes ABEND 0C4 at FEUSI002 error.
Problem conclusion
This fix is now available as part of IBM Z Development and Test Environment 12.0.5.0. Product web page: https://www.ibm.com/us-en/marketplace/z-systems-development-test -environment Fix List: https://www-01.ibm.com/support/docview.wss?uid=swg27044017
Temporary fix
Comments
APAR Information
APAR number
PH22573
Reported component name
ZD&T TOOLKIT
Reported component ID
5725G3923
Reported release
C00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-25
Closed date
2020-12-08
Last modified date
2020-12-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
extract
Fix information
Fixed component name
ZD&T TOOLKIT
Fixed component ID
5725G3923
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"C00"}]
Document Information
Modified date:
09 December 2020