Error description
When recording some HTTP messages using the RIT HTTP Proxy, responses are received with correct headers and HTTP status, but with no payload. The problem occurs when the HTTP server application sends replies without a content length header, and uses the end of connection to signify end of data. If a null character is included in the data stream, the proxy does not handle the payload correctly. These messages pass correctly through the HTTP Proxy when recording is not enabled.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users recording HTTP traffic using the Rational Integration * * Tester HTTP Proxy * **************************************************************** * PROBLEM DESCRIPTION: * * When recording an HTTP message with no content length * * header, and the payload contained a null character, no body * * was captured in Recording Studio. * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Rational Test Control Panel version 10.0.2.1 * ****************************************************************
Problem conclusion
Upgrade to IBM Rational Test Control Panel version 10.0.2.1 The newer HTTP Proxy code fixes this issue.
Temporary fix
Comments
APAR Information
APAR number
PH21883
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-06
Closed date
2020-03-20
Last modified date
2020-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSN
UP
R921 PSN
UP
R950 PSN
UP
RA00 PSN
UP
RA01 PSN
UP
RA02 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021